![bonitron M3575R Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/bonitron/m3575r/m3575r_customer-reference-manual_2787120028.webp)
M3575R
28
%
6
06
.
%
cycle
dec
duty
T
T
This rating assumes the application load will be linearly decreasing from peak
braking power to zero braking as the process comes to a stop.
Check this rating against the module
’s duty cycle rating, and if it is higher than
rated, select the next higher rated module. If a duty cycle is required over
20%, please call for assistance with your application.
7.1.4.
C
ONTINUOUS RATING
The continuous rating is listed for long term heating calculations should the
unit be installed in an area where heat dissipation is an issue. The rating is
based on a triangular cycle that starts at peak value and reduces to zero
within the rated duty cycle. Therefore, the average braking power during the
deceleration cycle is ½ the power required if full power were required during
the entire braking cycle. This value is:
2
/
%
*
duty
peak
continuous
P
P
For the above example, the
W
P
continuous
336
2
/
%
6
*
11190
7.2.
C
OMPETITIVE CROSS REFERENCE
Table 7-1: AB-To-Bonitron Shunt Cross-Reference
AB
S
HUNT
P/N
W
ATTAGE
(P
EAK
/
C
ONT
)
D
UTY
(M
AX
)
L
OAD
R
ES
.
(M
IN
/
M
AX
)
B
ONITRON
P/N
2090-SR020-36
32000 / 3600
11%
20
/ 25
M3575R-H33BF
2090-SR025-09
25600 / 900
3.5%
25
/ 31
M3575R-H27B0
2090-SR025-18
25600 / 1800
7%
25
/ 31
M3575R-H27BF
2090-SR040-09
16000 / 1800
5.5%
40
/ 50
M3575R-H16BF
2090-SR040-18
16000 / 1800
11%
40
/ 50
M3575R-H16BF
2090-SR120-09
5333 / 900
16%
117
/ 143
M3575R-H6MF
Содержание M3575R
Страница 6: ...M3575R 6 This page intentionally left blank ...
Страница 16: ...M3575R 16 Figure 3 2 Typical Braking Resistor Field Connections Dwg 070076 Rev 20070418 ...
Страница 20: ...M3575R 20 This page intentionally left blank ...
Страница 29: ...User s Manual 29 NOTES ...
Страница 30: ...M3575R 30 This page intentionally left blank ...
Страница 31: ......