background image

 

AHD 1200 Embedded PC 

 

General Information 

 

 

 

V1

 

 

1  General Information 

 

1.1  About this Manual 

Read this operation manual carefully before beginning any 
work! It is part of the product and must be kept in the prod-
uct’s immediate vicinity, so that it is always available to the 
personnel. 

Include this manual when passing the product on to third par-
ties. 

This operation manual provides important product handling infor-
mation. On the following pages, this manual describes the Embed-
ded PC AHD 1200.  

This manual includes specific instructions, in case additional, more 
detailed documentation is available for individual components.  

Adhering to all product safety and handling instructions for the 
product and all connected components is a prerequisite for safe 
operation. 

In addition, the local accident prevention and general safety rules 
for the device’s area of operation must be observed.  

The illustrations in this manual are intended to demonstrate the 
contents more clearly. They are not necessarily drawn to scale and 
can vary from the actual product in minor details. 

This operation manual must be viewed exclusively as a complete 
unit. It is not permitted to use excerpts from this manual as standa-
lone documentation without referring to the entire document. 

 

 

 

 

1.2  Explanation of Symbols 

   

Warnings 

In this manual, warnings are marked by symbols. The warnings are 
introduced by signal words indicating the degree of danger.   
 

It is important to heed these warnings and act with caution to 
avoid accidents, Personnel injury and equipment damage! 

       

 

DANGER

… indicates an imminently hazardous situation that 

can result in death or severe injury, if not 
avoided. 

 

 

WARNING

… indicates a potentially hazardous situation which 

can result in death or severe injury, if not 
avoided. 

 

 

Содержание AHD 1200

Страница 1: ...Inhaltsverzeichnis AHD 1200 Embedded PC Operation Manual Read this manual before beginning any work Dok ID PaJ 1045 V1 ...

Страница 2: ...2 V1 Böning Automationstechnologie GmbH Co KG Am Steenöver 4 D 27777 Ganderkesee Tel 49 0 4221 9475 0 Fax 49 0 4221 9475 21 22 E Mail info boening com Internet www boening com ...

Страница 3: ... 1 General Function 13 3 2 Mechanical Structure 13 3 3 Device Electronics 14 3 4 Interfaces 14 3 5 Electronic Data Processing 15 3 6 Configuration 16 4 Technical Information 17 4 1 Technical Data AHD 1200 17 4 2 Name Plate 18 4 3 Dimensions 19 4 3 1 Device Dimensions 19 4 3 2 Drill Holes 20 4 4 Connections 21 4 4 1 Device Connections 21 4 4 2 Terminal Assignment 21 5 Transport Packaging and Storag...

Страница 4: ...rring the Configuration 31 6 3 Initial Startup 32 7 Operation 33 7 1 Power On 33 7 2 Selecting the Video Source 33 7 3 Power Off 34 8 Maintenance 35 9 Errors 36 9 1 Safety 36 9 2 Error Correction 37 10 Disassembly 38 10 1 Safety 38 10 2 Disassembly 38 10 3 Disposal 39 11 Index 40 12 List of Abbreviations 41 ...

Страница 5: ... Embedded PC General Information V1 5 Change History for Operation Manual AHD 1200 Date Version Reason for Change Page Author 11 19 2012 AHD_1200_DOK_en_V1_20121119 New Creation Entire Document Patzke Jens PaJ ...

Страница 6: ...the local accident prevention and general safety rules for the device s area of operation must be observed The illustrations in this manual are intended to demonstrate the contents more clearly They are not necessarily drawn to scale and can vary from the actual product in minor details This operation manual must be viewed exclusively as a complete unit It is not permitted to use excerpts from thi...

Страница 7: ...perience of many years The manufacturer is not responsible for damages due to Noncompliance with the instructions in this manual Unintended use Employment of untrained personnel Unauthorized modifications and software changes Technical modifications Use of unauthorized spare parts The actual scope of delivery can vary from the explanations and il lustrations in this manual in case of customized mo...

Страница 8: ...pare Parts WARNING Risk of injury from incorrect spare parts Incorrect or defective spare parts can cause dam ages malfunctions or complete failure and jeo pardize the vessel s safety Therefore Only use the manufacturer s original spare parts Please order spare parts from a contracted reseller or directly from the manufacturer Refer to page 2 for the address 1 6 Warranty Terms The warranty terms c...

Страница 9: ...y abreast of the current workplace safety regulations and determine through a risk assessment any addi tional hazards resulting from the special working conditions of the product s place of use He must implement these in the form of operating instructions for the product s use During the product s entire period of operation the operator must verify that his operating instructions are in compliance...

Страница 10: ...ognize and avoid potential hazards independently due to formal training know ledge and experience as well as knowledge of the situational norms and regulations Electrician is able to work on electrical systems and recognize and avoid potential hazards independently due to formal training know ledge and experience as well as knowledge of the situational norms and regulations The electrician is trai...

Страница 11: ...rm monitoring and control system The device reads the supported protocols and sends the required information in real time to a redundant CAN bus or video inter faces for display on ship alarm displays In addition to data ga thered immediately from the ship s system other video source data can also be transmitted for viewing on displays WARNING Danger from unintended use Any use of the product beyo...

Страница 12: ...lfunctions can lead to Person nel injury or equipment damage in the overall sys tem Therefore Although the product itself is not especially dan gerous the effects of failures or malfunctions on the overall system must be considered Always discontinue using the products when they develop smoke or abnormal heat ...

Страница 13: ...s can be set up in the visualization configuration The configuration software AHD DeviceConfig configures the inte gration into the vessel s system Six CAN interfaces with standardized plug connectors are available for connecting the unit to the ship systems Data from external devices such as a GPS receiver can be read via the RS232 interface 3 2 Mechanical Structure Designed for wall mounting the...

Страница 14: ... the SAS protocol used CAN interfaces 5 and 6 are intended for the remote bus which provides commands for selecting video sources and controlling the displays from e g the display control units AHD DRM R and AHD DRM T The integrated RS232 interface can be used to connect e g a GPS receiver The video IN port BNC coupling receives data from an external video source e g a camera for viewing on a disp...

Страница 15: ...specific display settings When configuring data processing the properties of the captured system buses devices and their inputs and outputs are set up During the configuration of the system buses their functions ship alarm system engine monitoring watch standby system and con trol conning are also set up Furthermore basic settings for trig gering alarms their viewing on displays and the activation...

Страница 16: ...ssary to change the con figuration 3 6 Configuration When configuring the AHD 1200 one must distinguish between two configuration types System configuration with AHD DeviceConfig Visualization configuration with AHD Display Designer During the ship s system configuration with AHD DeviceConfig the AHD 1200 s integration into the ship s system is configured Among others this process determines how s...

Страница 17: ... mm maintain a mini mum distance of 70mm between cooling units and a wall when installing the device Weight appr 10 kg Environmental Data Operating Temperature 30 C 55 C 30 C 70 C at an interior console temperature of 45 C Storage Temperature 30 C 70 C Protection Class IP 20 Electrical Data Power Supply 24VDC 30 25 Performance appr 45W 24VDC Computer Processor 1 6 GHz Dual Core RAM 4GB Flash Disk ...

Страница 18: ...N Optocoupler Lum berg 8 pin coupling 5 x Relay OUT Relay Lumberg 8 pin plug Resolution DVI OUT 1024 x 768 pixels max XGA 1280 x 1024 pixels max SXGA Classifications In Progress GL DNV LR BV DNV ABS RMRS RINA CRS 4 2 Name Plate The Embedded PC AHD 1200 s name plate is located on the de vice front and contains the following information Model designation of the unit in the top section of the cover p...

Страница 19: ...AHD 1200 Embedded PC Technical Information V1 19 4 3 Dimensions 4 3 1 Device Dimensions ...

Страница 20: ...AHD 1200 Embedded PC Technical Information 20 V1 4 3 2 Drill Holes ...

Страница 21: ...data transfer from the AHD 1200 Pin 3 RxD data reception for the AHD 1200 Sig 5 GND Ground When connecting a GPS receiver or another device pin TxD is connected to the AHD 1200 s pin RxD and the device s ground is connected to the AHD 1200 s Ground pin Four optocoupler inputs intended for accepting acknowledge ments The pins are assigned as follows The maximum allowable voltage is 24V DC 30 25 RS2...

Страница 22: ...r Vcc Five relay outputs for controlling alarm indicators The pins are assigned as follows The relay outputs function is determined via configuration with AHD DeviceConfig 6 CAN plugs are used for connection to the vessel s CAN bus sys tem The pins are assigned as in the illustration Relay Out CAN ...

Страница 23: ... receipt Proceed as follows when noticing external transport damages Do not accept delivery or accept it only with reservation Note the scope of the damage on the transport documents or the deliverer s bill of lading File a claim TIP Claim any fault as soon as it is noticed Damage claims can only be filed within their respective rec lamation periods 5 3 Packaging About the Packaging The individual...

Страница 24: ...he local disposal regulations When necessary contract a specialist company Storage Store the packages under the following conditions Do not store them outdoors Store them in a dry dust free environment Do not expose them to aggressive media Protect them from sunlight Observe the storage temperature see technical data Avoid mechanical shock When storing longer than 3 months regularly inspect the ge...

Страница 25: ...ricians may work on the electrical system Basic Information Caution Risk of injury from improper installation and initial startup Improper installation and initial startup can cause Personnel injury and equipment damage Therefore Ensure sufficient installation space before be ginning any work Handle parts with exposed sharp edges careful ly Observe orderliness and cleanliness in the work area Inst...

Страница 26: ... their weight Install the products in such a manner that unau thorized persons cannot access the interfaces for the configuration Never bump or shake the products vigorously TIP When installing the AHD 1200 ensure that the de vice s interfaces can be accessed Installation Requirements All required connecting cables are of the required version equipped with plug connectors according to technical sp...

Страница 27: ...correct cable con nections Improperly connected cables can cause system errors and equipment damage Therefore Always verify cable and wire designations be fore connecting them Check for secure seating of the connecting wires in the terminals To avoid short circuits verify that all wires are connected in the terminal To not over tighten the terminal clamps When using pluggable terminal strips or pl...

Страница 28: ...ing installation can impair the device s tightness and lead to equipment dam age Ensure that the device is installed on even surfaces or in even panel cutouts without tilting Ensure that the drill holes in the device match ex actly the drill holes in the mounting surface Tighten the screws evenly and crosswise ...

Страница 29: ...UTION Equipment damage and system errors from missing ground If the AHD 1200 is not grounded equipment dam age and system errors may occur Therefore Ground the device during installation When grounding the device only use the des ignated M4 bolt marked red in the illustration ...

Страница 30: ...00 can lead to equipment damage and system errors Therefore Only install the devices in housings panels with air vents Select the installation location so that an air cur rent for cooling the devices can circulate The distance between the cooling elements and the closest housing console wall must be at least 70 mm so that proper cooling can be ensured ...

Страница 31: ... the device For this contact the manufacturer for further in formation 6 2 5 Transferring the Configuration TIP With factory side configured devices this step is only necessary for subsequent changes of the sys tem or visualization configuration For more information about transferring the system configuration consult the device s configuration instructions If you need to transfer the visualization...

Страница 32: ...quipment damage from incorrect voltage Connecting an incorrect supply voltage can lead to equipment damage Therefore Review all relevant project documents and op eration manuals of the devices used and verify their correct supply voltage and polarity before connecting them 4 Switch on the power supply of the AHD 1200 and all con nected external devices from the corresponding circuit break ers in t...

Страница 33: ...st be switched on to establish complete and error free system operation The Embedded PC AHD 1200 does not include its own switch for powering the device on and off The AHD 1200 is powered on by switching on its power supply in the corresponding distribution box Upon successful startup the Windows XP Embedded start screen or another visualization set up in the configuration is shown on a display co...

Страница 34: ...tivate all power supplies for the entire system powering down the system completely When doing this observe the operation manuals of the devices The Embedded PC AHD 1200 does not include its own switch for powering the device on and off The AHD 1200 is powered off by switching off its power supply in the corresponding distribution box The PC does not require a special shutdown procedure The de vic...

Страница 35: ...ction Only use solvent free nonabrasive detergents for cleaning CAUTION Risk of injury from dangerous voltages and other hazards Opening covers can expose you to dangerous vol tages or other hazards Therefore Never perform device repairs yourself Do not remove the covers for maintenance or inspection In case of product malfunctions contact the manufacturer or an authorized representative ...

Страница 36: ...other hazards Opening the covers can expose you to dangerous voltages or other hazards Therefore Never perform device repairs yourself Do not remove the covers for maintenance WARNING Risk of injury from improper error correction Improper error correction can cause severe Per sonnel injury or equipment damage Therefore Only the manufacturer or authorized personnel may repair the device Ensure suff...

Страница 37: ...ure Test the power supply No connection to video source Test the connection to the video source No connection to the display Test the connection to the display Incorrect data processing and visualization of external data although the device and sys tem are connected to the power supply and to each other Device defect Contact the manufacturer or an autho rized representative if the device does not ...

Страница 38: ... space before beginning any work Use caution when handling parts with exposed sharp edges Observe orderliness and cleanliness in the work area Parts and tools that are loosely stacked or lying about are accident sources Uninstall parts properly When in doubt consult the manufacturer 10 2 Disassembly Before beginning disassembly disconnect the device from the power supply and secure it against reco...

Страница 39: ...ts according to their material properties CAUTION Environmental damages from improper dispos al Electrical scraps electronic components lubri cants and other auxiliary materials are subject to hazardous waste regulations and may only be dis posed by licensed specialist companies Your local authorities or specialized disposal companies can pro vide you with information about environmentally safe di...

Страница 40: ...ion 26 28 Intended Use 11 Interfaces 14 L Limitation of Liability 7 M Maintenance 35 Mechanical Structure 13 N Name Plate 18 O Operation 33 Power Off 34 Power On 33 Selecting the Video Source 33 Operator s Responsibilities 9 P Packaging 23 Personnel Disassembly 38 Electrician 10 Errors 36 Initial Startup 25 Installation 25 Requirements 10 Specialist 10 Trained Person 10 S Safety 9 Spare Parts 8 St...

Страница 41: ...g C CAN Controller Area Network S CRS Croatian Register of Shipping SXGA Super Extended Graphics Array D U DNV Det Norske Veritas USB Universal Serial Bus DVI Digital Visual Interface V E VGA Video Graphics Array ECDIS Electronic Chart Display and Information System X G XGA Extended Graphics Array GL Germanischer Lloyd GTC General terms and conditions L LED Light Emitting Diode LR Lloyd s Register...

Страница 42: ...echnology Ship Automation Böning Automationstechnologie GmbH Co KG Am Steenöver 4 D 27777 Ganderkesee E Mail info boening com Internet www boening com Texts and illustrations not binding We reserve the right to make changes due to technical improvements ...