TECHNICAL DATA
DESCRIPTION
Multidea Evo - Multidea Evo M
60
100
115
Fuel
G20 (20 mbar) - G30(28-30 mbar) - G31 (37 mbar)
Country(s) of destination
EU
Appliance category
II2H3B/P
Type of appliance
B23P, C13, C33, C43, C53, C63, C83
Max. nominal heating output (Qn)
55.1
94
107
kW
Min. heating output (Qmin)
7.0
11.8
15
kW
Nominal heating output (80-60°C)
53.2
91.2
104.0
kW
Energy saving heating output (80-60°C)
6.7
11.3
14.5
kW
Nominal heating output (50-30°C)
57.5
98.5
112.5
kW
Energy saving heating output (50-30°C)
7.5
12.6
16.1
kW
EFFICIENCY
Useful efficiency at max. Pn (80-60°C)
96.6
97.0
97.2
%
Useful efficiency at min. Pn (80-60°C)
95.8
96.0
96.5
%
Useful efficiency at max. Pn (50-30°C)
104.3
104.8
105.1
%
Useful efficiency at min. Pn (50-30°C)
107.2
106.8
107.0
%
Useful efficiency at 30% load (return 30°C)
108.6
108.0
108.3
%
Max. gas consumption (G20)
5.83
9.95
11.32
m
3
/h
Min. gas consumption (G20)
0.74
1.25
1.59
m
3
/h
Max. gas consumption (G30)
4.35
7.41
8.44
kg/h
Min. gas consumption (G30)
0.55
0.93
1.18
kg/h
Max. gas consumption (G31)
4.28
7.30
8.31
kg/h
Min. gas consumption (G31)
0.54
0.92
1.17
kg/h
EMISSIONS
Flue temperature (80-60°C) at Qn
65 - 75
°C
Flue temperature (80-60°C) at Qmin
55 - 60
°C
Flue temperature (50-30°C) max/min
40 - 45
°C
Mass flue flow rate at Qn
0.0259
0.0450
0.0498
kg/sec
Mass flue flow rate at Qmin
0.0035
0.0059
0.0073
kg/sec
Mass air flow rate at Qn
0.0247
0.0430
0.0476
kg/sec
Mass air flow rate at Qmin
0.0033
0.0056
0.0069
kg/sec
Max. condensate production min/max
2.2/8.6
3.7/14.6
5.3/16.7
l/h
Max/min CO2 (G20)
9.3/8.8
9.1/8.7
9.4/9.0
%
Max/min CO2 (G30)
11.8/11.2
11.8/11.6
11.8/10.6
%
Max/min CO2 (G31)
10.1/9.6
9.9/9.4
10.2/9.4
%
Weighted CO
18
13
11
mg/kWh
Weighted NOx
64
28
30
mg/kWh
NOx CLASS
5
ELECTRICAL DATA
Max. electrical absorption
Multidea Evo
165
415
595
W
Max. electrical absorption
Multidea Evo M
103
335
680
W
Power supply voltage
230
~
50
V
~
Hz
Protection rating
IPX4D
BOILER
Max. operating pressure
6
bar
Max. operating temperature
90
°C
Boiler water content
5.5
8.0
8.7
l
Residual heat at nominal ∆t (20°C)
110
130
580
mbar
ΔT Maximum supply/return
35
Water flow rate at nominal ΔT (20°C)
2.29
3.92
4.47
m
3
/h
FLUE EXHAUST
Flue exhaust/air inlet fitting ø
80/80
100/80
100/80
mm
Max. length of cond. drain 80/125
5
5
3
m
Max. length of separate pipes 80/80
19
17
10,5
m
Residual air/flue head available
117
348
270
Pa
BLOWER
Speed at nominal heating capacity
G20
5700
7200
7300
rpm
Speed at minimum heating capacity
G20
1250
1450
1600
rpm
Speed at nominal heating capacity
G30
5100
6100
6500
rpm
Speed at minimum heating capacity
G30
1150
1250
1450
rpm
Speed at nominal heating capacity
G31
5700
7000
7500
rpm
Speed at minimum heating capacity
G31
1250
1400
1600
rpm
Speed at ignition heating capacity
G20
3500
2850
3350
rpm
Speed at ignition heating capacity
G30-G31
5100-4800
3200-3300
3700-3900
rpm
DIMENSIONS and WEIGHTS
Width
600
mm
Depth
480
480
560
mm
Height
900
mm
Weight
68
88
98
kg