7 / 32
IOM BX-BE-BN-MX-ME-M_eng - Translation of original instructions in Italian - Rev 02_0 - 30/09/16
Single-speed motors
Two-speed motors
Delta connection
Single winding (Dahlander)
Low
speed
Low
speed
High
speed
High
speed
Two separate winding
Star connection
4.3
Ventilation
Motors are cooled through outer air blow (IC 411 according to CEI EN 60034-6) and are equipped
with a plastic radial fan, which operates in both directions.
Ensure that fan cover is installed at a suitable distance from the closest wall so to allow air circulation
and servicing of motor and brake, if fitted.
On request, all BX/MX, BE/ME motors and BN/M motors, starting from BN 71 or M1 size, can be sup-
plied with independently power-supplied forced ventilation system.
Motor is cooled by an axial fan with independent power supply and fitted on the fan cover (IC 416
cooling system).
Brake motors of BN_BA type and all motors with rear shaft projection (PS option) are excluded.
U1
V a.c. ± 10%
Hz
P [W]
I [A]
BN 71
M1
1 ~ 230
50 / 60
22
0.12
BN 80
M2
22
0.12
BN 90
—
40
0.30
BN 100
M3
50
0.25
BN 112
—
3 ~ 230 / 400Y
50
0.26 / 0.15
BN 132 ... BN 160MR
M4
110
0.38 / 0.22
BN 160M ... BN 180M
M5
50
180
1.25 / 0.72
BN 180L ... BN200L
—
250
1.51 / 0.87
V a.c. ± 10%
Hz
P [W]
I [A]
BX 80 - BE 80
MX2 - ME2
1 ~ 230
50 / 60
22
0.12
BX 90 - BE 90
—
40
0.30
BX 100 - BE 100
MX3 - ME3
50
0.25
BX 112 - BE 112
—
3 ~ 230 / 400Y
50
0.26 / 0.15
BX 132 - BE 132
MX4 - ME4
110
0.38 / 0.22
BX 160 - BE 160
MX5 - ME5
50
180
1.25 / 0.72
BX 180 - BE 180
—
250
1.51 / 0.87
Fan wiring terminals are housed in a separate terminal box
4.4
Ratings of separate supply fan units