Page | 9
Installation
BONAIRE WINDOW COOLER
Unit Installation
DO NOT
connect the power to the cooler until the installation is complete.
Internal Fixing of the Unit
IT IS MANDATORY THAT THE METAL FIXING BRACKETS SUPPLIED ARE FITTED TO
ENSURE A SECURE INSTALLATION.
Utilise the 2 fixing brackets and 8 screws provided (4 x
Screw
– 16mm Hi-Lo hex head and 4 x Screw – No. 8 x 1¼ pozi-drive) as shown in the diagram
to ensure the unit is adequately locked into position.
Ensure that the bracket is aligned within the indicated mounting track area on the underside of
the fan housing
– see diagram below. Drill 2x1/8” (3.2mm) holes and insert screws into unit as
per diagram and repeat for window frame with appropriate screws.
Ensure that the cooler is now fixed rigidly to the house structure
Close window against unit. Measure the gap of the
opening & cut the in-fill panel to fit in the gap left.
Fit in fill panel with screws (length of screws must not
exceed 25mm
(1”) in length) and seal any gaps with
silicone.
Check that the unit is still level using spirit level on top
edge of Rear Filter Panel.