background image

MORTAR MIXES CON’T

1. A richer mix will work more easily through the gun.

2. If your mortar mix is plugging or the Quikpoint is laboring

to put your mix out, then use Gibco’s-MRF additive or a
good plasterisizer.

A. Shake before using Gibco’s-MRF pump aid additive.

B. Add to mixing water

1/2

oz. of Gibco’s-MRF to 1

gallon of water. Do not exceed 3 oz. of MRF to 5
gallons of water.

C. MRF is a lime substitute. If there is lime in the mix,

reduce the amount of MRF to

1/2

oz. per 2 gallons of

water.

D. Do not use high speed drill mixers. MRF will slighty

air entrain and may alter (lighten) color in the mortar.

TROUBLESHOOTING

1. Tool is not delivering mortar out of nozzle

A. Make sure drill is in forward rotation. Tool will not

deliver mortar in reverse.

B. Make sure set screws on Cam-Coupling and

Blade-Coupling are tight.

C. Make sure the Cam-Roller is in place and that the

Vibrator is working in the Hopper. The Vibrator will
not work if the Roller is not on the Vibrator Rod.

D. Inspect auger for wear. Take the Nozzle-Holder off

and look down the inside of the Barrel. If there is a
gap of

1/8

” or more around the Auger, then the Auger

needs to be replaced. If the Auger is not warn and
there is a similar gap, then the Auger-Barrel needs to
be replaced.

2. The Tool Plugs

A. Check to see that the Nozzle-Holder, Steel Nozzle and

Plastic Retainer are assembled in the correct order.
the Steel Nozzle is inserted first followed by the
Retainer.

B. If the tool plugs, remove the Nozzle-Holder. Holding

Nozzle-Holder on hard surface to remove stiff mortar.
Keeping hands away from Tip-Blades, run drill in
forward to dislodge any obstructions in the Auger-
Barrel. Clean the end of the Auger-Barrel and Nozzle-
Holder assembly with water. Reinstall Nozzle-Holder
and run.

C. If problem continues, check the Tip Blades (#503) and

U-Blade (#504) for wear. The Long-Blade should be
flush or no more than

1/8

” back from the front of the

Steel-Nozzle. If wear is noted, replace worn parts.
Note: The U-Blade (#504) usually does not have to be
replaced until 3 or 4 sets of Tip-Blades (#503) have
been replaced.

D. If problems persist, see mortar mix information page.

3. If Nozzle-Holder does not rotate for Vertical and

Horizontal action, remove Petroleum Jelly to the o-ring and
Allen Key stop area of the Auger-Barrel

4

4430 Gibsonia Rd. • Gibsonia, PA 15044 • USA • www.bontool.com

3

4430 Gibsonia Rd. • Gibsonia, PA 15044 • USA • www.bontool.com

IS14188 08/09

PAGE 4 OF 4

Содержание 14-188 Quickpoint

Страница 1: ...s steel set screws 1 Extra nozzle key Allen wrench 1 16 oz Scoop no 554 1 8 oz Gibco s MRF Tip blades can be made from 1 8 electrician s snake Bend with pliers and vice to contour below or send for replacement tips A set consists of one long one short blade and on U blade Insert this end in blade coupling Caution Protect eyes when cutting hardened wire NOZZLE ASSEMBLY 1 Drop metal nozzle tip into ...

Страница 2: ... on to Barrel 8 Push Nozzle holder on until the Allen Key 506 easily slides into locking hole MOUNTING A DRILL 1 We recommend removing the chuck from the drill and threading the Cam Coupling on to the drill mandrell this makes the whole assembly shorter with much better balance Some drills have a left threaded Reversing Screw holding the chuck onto the drill Open the chuck all the way Then looking...

Страница 3: ...le 552 A for overhead applications CLEANING AND MAINTENANCE 1 Do not leave mortar in gun for more than one hour 2 To clean gun flush with water while gun is run ning Do not use water hose to clean tool Use only a small con tainer to direct water into the hopper without spilling Caution Keep water off of drill Do not immerse tool in water if drill is attached 3 Unplug drill Remove nozzle and clean ...

Страница 4: ... Auger then the Auger needs to be replaced If the Auger is not warn and there is a similar gap then the Auger Barrel needs to be replaced 2 The Tool Plugs A Check to see that the Nozzle Holder Steel Nozzle and Plastic Retainer are assembled in the correct order the Steel Nozzle is inserted first followed by the Retainer B If the tool plugs remove the Nozzle Holder Holding Nozzle Holder on hard sur...