background image

ELECTRICAL

Volume 2

Flight Crew Operating Manual

Sep 14/2005

07-01-18

CSP 100-6

REV 4

EICAS MESSAGES

The electrical system messages are shown on the EICAS. In the table below is a list of the electrical system messages,
inhibits, and aural warnings. A brief explanation of each message is provided.

MESSAGE

INHIBITS

MEANING

AURAL 

WARNING

L (R)

BATT OVERHEAT

TO/LAND

Respective battery internal temperature 
exceeded 70 

°

C

ESSENTIAL POWER 

ONLY

The essential buses are powered by the batter-
ies only. AUX and MAIN buses are automati-
cally deactivated in flight

APU GEN FAIL

TO/LAND

 The APU generator failed

APU GEN OVERLOAD

TO/LAND

 The APU generator has exceeded 500 amp

L (R) BATT FAIL

TO/LAND

Either the respective battery contactor failed or 
the battery has been automatically discon-
nected for overheat protection

ELEC HYD GEN FAIL 

TO/LAND

The hydraulic generator has failed to come on-
line

ELECTRICAL FAULT

TO/LAND

An electrical system failure has occurred that 
prevents display of electrical indications

L (R) GEN FAIL

TO/LAND

The affected generator has failed. If the APU 
generators not on line, the BUS-TIE will auto-
matically close and, in-flight, the auxiliary buses 
will not be powered

L (R) ESS BUS FAIL

TO/LAND

Affected bus is not powered 

L (R) 

GEN OVERLOAD

TO/LAND

Respective generator load exceeded 500 amp

L (R) MAIN BUS FAIL

TO/LAND

The affected MAIN bus is not powered 

L (R) AUX BUS FAIL

TO/LAND

The affected auxiliary BUS is not powered with 
a power source available

L (R) AUX BUS OFF

TO/LAND

Respective AUX BUS is selected off

ELECTRICAL FAULT

TO/LAND

An electrical system fault occurred, resulting in 
loss of redundancy in the display of electrical 
indications

4

Содержание Challenger 300

Страница 1: ...Pilot Circuit Breaker Panel Typical 07 01 07 CB 2 Copilot Circuit Breaker Panel Typical 07 01 08 CB 3 Left Side Equipment Rack Circuit Breaker Panel Typical 07 01 09 CB 4 Right Side Equipment Rack Ci...

Страница 2: ......

Страница 3: ...ation A separate battery powers the independent standby instrument system An optional hydraulically driven electrical generator is available to provide electrical power generation in the event all eng...

Страница 4: ...INTRODUCTION Cont RIGHT CIRCUIT BREAKER PANEL RIGHT SECONDARY POWER CENTER LEFT CIRCUIT BREAKER PANEL LEFT SECONDARY POWER CENTER RIGHT DC POWER CENTER RIGHT BATTERY LEFT GENERATOR APU GENERATOR EXTER...

Страница 5: ...y are fed by the distribution buses of the secondary distri bution centers and distribute electrical power to loads which require pilot access to the associated circuit breaker The electrical system i...

Страница 6: ...cation of amps drawn from the GPU is provided With the external power cable connected the following indications are annunciated on the ELECTRICAL synoptic display EXT PWR symbol and line are white whe...

Страница 7: ...ment for a limited duration Standby Instrument power is supplied by a dedicated 24 vdc battery The standby instrument is activated by a separate STBY INST switch located on the ELECTRICAL power panel...

Страница 8: ...LECTRICAL cockpit control panel CIRCUIT BREAKER PANELS Two circuit breaker panels are located in the cockpit and are fed by the distribution buses of the secondary power centers They distribute power...

Страница 9: ...D L DCP L PFD ATT HDG 1 AIR DATA 1 DISPLAYS INDICATING RECORDING L BLEED VALVES PRESS 1 PACK ENVIRONMENTAL DCU A RDC A CTRL 1 L PWR 1 R PWR 2 ANNUNCIATOR L PITOT TAT VANE CASE CTRL PWR L ENG INDICATIN...

Страница 10: ...WR 2 L DC PUMP PTU R SOV R IND LDG GEAR HYDRAULIC DISPLAYS INDICATING RECORDING FDR L PWR 2 R PWR 1 CTRL 2 RDC B DCU B ANNUNCIATOR EMER DOME LIGHTS R ENG R WING BLD LK PWR CTRL R ICE DET CASE VANE R S...

Страница 11: ...NGINE ELEC L ENG SOV GRAVITY X FLOW QTY 1 FUEL FLIGHT CONTROL PAX DOOR ENVIRONMENT L SIDE WINDOW ANTI ICE L FORCE SNSR MSTR DISC AUTO FLT TRIM ENTRY LIGHTS L CKPT PED CABIN SIGNS WING INSP MAP STOW BC...

Страница 12: ...DJ AUTO FLT TRIM MSTR DISC FLIGHT CONTROL CABIN LIGHTS BUS CTRL PWR 1 PWR 2 INDICATING RECORDING 3 3 3 3 3 3 3 3 5 3 3 3 5 50 50 10 3 5 10 NORM 20 HYD GEN APU GEN R GEN R BATT SEC BUS 7 5 3 PWR TEST H...

Страница 13: ...BUS L SPC BAT BUS R DCPC ESS BUS AVNX ENGINE FIREX FCTL LIGHTS ELECTRICAL EXT BAG AFT BAY 5 5 25 5 3 3 7 5 25 5 CFO0106002_002 FAN PWR 1 AVNX 35 PWR 2 GROUND SERVICE PWR 1 25 25 ELECT 5 EDC PWR HF 2 P...

Страница 14: ...L BATT BUS CBP R ESS BUS CBP R MAIN BUS CBP R BATT BUS CBP CB2 C6 STBY INST R ESS BUS SPC R MAIN BUS SPC R AUX BUS SPC R BATT BUS SPC R BATT BUS DCPC R ESS BUS DCPC R MAIN BUS DCPC R AUX BUS DCPC L SE...

Страница 15: ...U APU STRT RIGHT GEN LEFT AUX BUS LEFT MAIN BUS LEFT ESS BUS RIGHT ESS BUS RIGHT MAIN BUS RIGHT AUX BUS LBAT BUS RBAT BUS R BATT OFF R GEN OFF L GEN OFF CAGE STD B R T D I M BARO 240 220 200 180 M 47...

Страница 16: ...ght Crew Operating Manual May 06 2005 07 01 14 CSP 100 6 REV 2 CONTROLS AND INDICATIONS EXTERNAL POWER CONTROL PANEL CFO0501002_006 EXTERNAL POWER CONTROL PANEL ON Gnd Service EXT DC AVAIL IN USE APU...

Страница 17: ...t Crew Operating Manual Volume 2 REV 1 CSP 100 6 07 01 15 CONTROLS AND INDICATIONS Cont ELECTRICAL SUMMARY PAGE CFO0701002_009 CAS CKLST SKIP FRMT TFC TR WX ENTER A ICE FLT FUEL HYD L R ECS AUTO PLAN...

Страница 18: ...Motor Driven Generator HMDG system CFO0701002_010 EXT PWR L BATT R BATT OFF AVAIL ON ELECTRICAL OFF OFF OFF ON BUS TIE L GEN APU GEN R GEN R ESS R MAIN R AUX L ESS L AUX L MAIN STBY INST OFF CFO07010...

Страница 19: ...TRIM V T 600 600 93 0 61 0 NI MACH HOLD ITT N2 OIL PRESS OIL TEMP FF PPH 84 7 46 115 7300 84 7 46 115 7300 APU RPM 100 250 APU EGT FUEL QTY LBS TOTAL 12000 6000 6000 S T A R T S T A R T STAB AIL LWD...

Страница 20: ...d or the battery has been automatically discon nected for overheat protection ELEC HYD GEN FAIL TO LAND The hydraulic generator has failed to come on line ELECTRICAL FAULT TO LAND An electrical system...

Страница 21: ...f the standby instrument battery have failed APU GEN OFF APU GEN switch has been selected OFF L R BATT OFF The affected battery has been selected OFF BUS TIE MAN OPEN The bus tie has been manually sel...

Отзывы: