background image

DESCRIPTION

The Bogen Model WMK

1

is a flush in-wall mounting cabinet

designed to accommodate Models C

1

0/C

1

0MOH,

C20/C20MOH, CAM, and CAM2.The cabinet fits between stan-
dard 2 x 4’s on 

1

6" center wall studs, with the front panel act-

ing as a plaster ring. Controls are accessible via a tilt-open door
that may be locked in either the closed or open position. The
cabinet is finished in black and is made from sturdy 

1

6-gauge

steel. It is supplied with a backbox which includes an easily
mounted AC power receptacle.

DIMENSIONS & WEIGHT

Wall Box

1

4"W x 

1

3-

1

/2"H x 3-

1

/2"D

Face Plate

1

6"W x 

1

4-

1

/2"H

Tilt-Open Door

11

-5/8"W x 8-3/8"H

Minimum, Opening Required

1

4-

1

/8"W x 

1

3-5/8"H 

Shipping Weight

1

3 lbs.

INSTALLATION

ACCESSIBILITY:

The backbox must be placed so that the

controls are at an appropriate height for operation.Typically, the
bottom of the backbox should be three feet above the floor.

MOUNTING:

The flush-mounting backbox must be secured

to support surfaces inside the wall or, in new construction, must

be built into the wall.The WMK

1

is shipped with the front panel

and door assembly temporarily secured to the backbox. Remove
the assembly from the backbox and mount the box with four
screws through the slotted holes (see mounting diagram on the
back of this sheet). Use these slotted holes to position the box
so that it is flush with the surface of the finished wall.When this
is accomplished, add four more screws through the holes just
forward of the slotted holes. Securely tighten all eight screws to
prevent any further movement of the backbox.The AC recepta-
cle must be located at the top of the backbox.The wall cutout
for the backbox should be 

1

4-

1

/8" wide and 

1

3-5/8" high.

WIRING:

The backbox has a ½" conduit entry above the

receptacle box which must be used for AC line connection. (This
is the knockout between two small screw holes.) Where possi-
ble, locate the backbox near a suitable #

1

4 AWG, 3-wire single-

phase,

1

20V AC line. Use wire nuts to connect the receptacle.

The box must be convenient for connection of microphone
input cables and speaker lines.All wires enter the box inside the
wall.

CAUTION

Do not locate box or connecting wires near steam lines or other heat
sources.

INSTALLATION OF THE AMPLIFIER:

The amplifier is

secured to the door of the WMK

1

by four screws.A separately

mounted flange on the door provides a stop for the door and,
when removed, allows the amplifier to be dropped down for
connections. Audio cables may be brought into the backbox
through any knockout other than that used for the AC line.

• Tilt-open door
• Can be locked in closed or open position
• Used with models C

1

0/C

1

0MOH, C20/C20MOH,

1

0- and

20-watt amplifiers, and CAM or CAM2 mixer amplifiers

MODEL WMK

1

WALL MOUNT CABINET

© 2000 Bogen Communications, Inc.
Printed in U.S.A. All rights reserved. 54-5634-07R2 00

11

Отзывы: