MAINTENANCE
There are no user serviceable parts inside
the unit and removal of the dust cover pre-
servicing should be attempted only by a
BOGEN SERVICE
We are interested in your Bogen tuner for as long as you
have it. If trouble ever develops with your unit, please do
not hesitate to ask our advice or assistance. Write to Ser-
vice Department, Bogen Division, Lear Siegler, Inc., P.O.
Box 500, Paramus, New Jersey 07652.
When communicating with us, give the model number
and serial number of your unit. Describe the difficulty
encountered and the effects each operating control has
upon the trouble symptoms. Include details on electrical con-
nections to associated equipment, and list such equipment.
When we receive this information, we will send you service
information if the trouble appears to be simple. If the trouble
requires servicing, we will send you the name and address
of the nearest Bogen authorized service agency to which you
can send your unit for repairs.
When shipping your unit, pack it carefully using the
original shipping carton, or a similar container and filler
material, to prevent damage in transit. Send the unit, fully
insured and prepaid, via railway express or United Parcel.
Do not ship via parcel post unless so instructed.
DIAL CORD RESTRINGING.
Refer to figure 5 and proceed
as follows:
a) Remove front panel by pulling off TUNING knob and
removing two Phillips-head screws.
b) Connect dial cord at drum hook marked START in
diagram.
c) String dial around nylon pulleys and tuning shafe to
drum hook marked FINISH in diagram. Make certain cord
winds around tuning shaft from rear toward front, as shown.
d) Attach end of cord with tension spring, making certain
that spring applies enough pressure to prevent cord from
slipping.
e) Tune in a known station and attach dial pointer at proper
position. Before securing pointer, twist cord as shown in
diagram so cord will exert a slight pressure toward panel
bracket and away from dial glass.
REPLACING DIAL LAMP.
Remove front panel as described
in step a), above, and replace lamp with 6.3V No. 12 bulb
(Bogen Part 94-0175-01).
REPLACEMENT PARTS
Most components used in the Model TP160 are avail-
able through all reputable parts jobbers. The parts listed
here are available from Bogen distributors, service agencies
or directly from the factory.
When ordering parts from Bogen, specify the part num-
ber and description, as listed below. Also give the Model
TP160 and the Series designation, which is a letter followed
by numbers stamped or screened on rear of the chassis.
When ordering a part for the PC Board, also give the PC
Board component number, which is 45-9764-01.
P U L L E Y
(SIDE
V I E W
)
.
POINTER
(FRONT VIEW)
C74--1744
* PROPER LENGTH WHEN SPRING IS STRETCHED TO I’:
Figure 5 - Dial Stringing Diagram
4