![Bogen Nyquist NQ-S1810CT-G2 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/bogen/nyquist-nq-s1810ct-g2/nyquist-nq-s1810ct-g2_configuration-manual_2784495012.webp)
10
The following table describes the
Configuration Settings
tab settings:
The
Configuration Settings
tab also displays the following information for each
Device
Station
attached to the amplifier:
Table 5. Configuration Settings (Standalone disabled)
Get Configuration from
Server
Retrieves configuration settings (i.e., web username,
server, and local port) from the TFTP server specified in
the Network Settings (see
).
Web Username
Identifies the username of the current user.
Emergency-All-Call
Identifies the IP address, port number, cut level (vol
-
ume), and station list used for emergency all-call
pages.
All-Call
Identifies the IP address, port number, cut level (vol
-
ume), and station list used for all-call pages.
Audio Distribution
Identifies the IP address, port number, cut level (vol
-
ume), and station list used for audio distribution.
Multicast #
Identifies the IP address, port number, cut level (vol
-
ume), and station list used for the multicast audio
stream of one (or more) zones.
Port Number
Identifies the port number of the appliance.
Port Type
Identifies the device type to which the port connects.
Account ID
Identifies the SIP account (IP address) associated with
the device preceded by the extension of the device
associated with this port.
Local Port
Identifies the port used for SIP.
Username
Identifies the username or extension for the station
associated with the port.