Connector J40
Connector J40 provides relay driver outputs for each station which goes active whenever the program or intercom
relay for that station goes active. The pin-outs for J40 are shown in Figure 13. By cutting the proper diode, the out-
put can be made to go active when one or the other relays activate. Refer to Figure 13 and the following example: If
Diode D49 (near program Relay K1) is removed, the output S1RY (on the J40 connector) will go active only when
relay K25 (intercom) is activated. Conversely, if diode D73 (near intercom relay K25) is removed, the output S1RY
will go active only when relay K1 (program) is activated.
Optional circuitry is available at the J40 accessory which can be used to control external bells or other external
devices. Contact Bogen Application Engineering for assistance.
Station 1, Pin 1
N/C
N/C
N/C
N/C
N/C
N/C
N/C
PIN 16, GND
PIN 18, GND
PIN 20, GND
N/C
N/C
N/C
N/C
Station 24, Pin 30
Station 23, Pin 32
Station 22, Pin 34
Station 21, Pin 36
Station 20, Pin 38
Station 19, Pin 40
Station 2, Pin 3
Station 3, Pin 5
Station 4, Pin 7
Station 5, Pin 9
Station 6, Pin 11
Station 7, Pin 13
Station 8, Pin 15
N/C
N/C
Station 18, Pin 21
Station 17, Pin 23
Station 16, Pin 25
Station 15, Pin 27
Station 14, Pin 29
Station 9, Pin 31
Station 10, Pin 33
Station 11, Pin 35
Station 12, Pin 37
Station 13, Pin 39
J40
Relay Coil
(with 1N
4004 Diode)
( + )
Power Supply
(12V DC)
( - )
Figure 13 - J40 Stations to Pin # Schematic