50 Spring Street, Ramsey, NJ 07446, U.S.A.

Tel. 201-934-8500 • Fax: 201-934-9832

www.bogen.com

The 

Bogen HTA125A & HTA250A Power Amplifiers

are warranted to be free from defects in material and workmanship for two (2) years from

the date of sale to the original purchaser. Any part of the product covered by this warranty that, with normal installation and use,
becomes defective (as confirmed by Bogen upon inspection) during the applicable warranty period, will be repaired or replaced by Bogen, at
Bogenʼs option, provided the product is shipped insured and prepaid to: Bogen Factory Service Department, 50 Spring Street, Ramsey, NJ 07446,
USA. Repaired or replacement product will be returned to you freight prepaid. This warranty does not extend to any of our products that have
been subjected to abuse, misuse, improper storage, neglect, accident, improper installation or have been modified or repaired or altered in any
manner whatsoever, or where the serial number or date code has been removed or defaced.

THE FOREGOING LIMITED WARRANTY IS BOGENʼS SOLE AND EXCLUSIVE WARRANTY AND THE PURCHASERʼS SOLE AND

EXCLUSIVE REMEDY. BOGEN MAKES NO OTHER WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, AND ALL IMPLIED

WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED AND EXCLUDED TO

THE MAXIMUM EXTENT ALLOWABLE BY LAW. 

Bogen's liability arising out of the manufacture, sale or supplying of products or their use or

disposition, whether based upon warranty, contract, tort or otherwise, shall be limited to the price of the product. 

IN NO EVENT SHALL BOGEN

BE LIABLE FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS,

LOSS OF DATA OR LOSS OF USE DAMAGES) ARISING OUT OF THE MANUFACTURE, SALE OR SUPPLYING OF PRODUCTS, EVEN IF

BOGEN HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSSES.

Some States do not allow the exclusion or limita-

tion of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights,
and you may also have other rights which vary from State to State.

Products that are out of warranty will also be repaired by the Bogen Factory Service Department – same address as above or call 201-934-8500.
The parts and labor involved in these repairs are warranted for 90 days when repaired by the Bogen Factory Service Department. All shipping
charges in addition to parts and labor charges will be at the owner's expense. All returns require a Return Authorization number. For most
efficient warranty or repair service, please include a description of the failure.

12/2008

Limited Warranty; Exclusion of Certain Damages

Содержание HTA125A

Страница 1: ...Specifications subject to change without notice 2010 Bogen Communications Inc All rights reserved 54 5832 04B 1011 HTA125A 250A Power Amplifiers Installation Use Manual ...

Страница 2: ...not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If ...

Страница 3: ... to Chassis 2 120V AC Outlet Not Switched 3 AC Line Fuses 4 Output Connections 5 Balanced Input Accessory Transformer Required 6 Unbalanced Input 7 Input Level Adjustment 1 Overload Shut Down Indicator 2 ON OFF Power Switch 1 2 4 5 6 7 1 2 2 3 4 5 6 7 3 FRONT PANEL REAR PANELS 1 ...

Страница 4: ...nections AC Line Fuse and an Auxiliary Re ceptacle A Low Cut Filter switch is located internally on the printed circuit board Rack Mounted Installation The amplifier is designed for installation in a standard 19 equip ment rack Position the unit in the rack and secure with screws through the amplifier front panel NOTE Before placing the amplifier in a rack install any accessory transformers requir...

Страница 5: ...s a 25V or 70V speaker output Connect the output of the driver amplifier to the HI Z INPUT jacks via a resistor network The resistors shown in Fig 1 are in addition to the normal loudspeaker load on the output of the driver amplifier Input Connections Fig 1 Input From Another Amplifier AT 70V R1 10K 1 2W AT 25V R1 3 3K 1 2W 70V R1 R2 100 1 2W GND OUTPUT TERMINAL STRIP OF DRIVER AMPLIFIER TO HIGH I...

Страница 6: ... to the amplifier Turn the adjustable screw clock wise to increase the level Warning Many loudspeakers may be damaged if overdriven Therefore always begin system setup with the input level control fully counterclockwise and gradually increase the setting to ob tain the desired output level Overload Shutdown Indicator Electronic shutdown circuitry activates whenever an overload or short occurs on t...

Страница 7: ...ut level control Slo Blo fuse Internal Low Cut filter switch Power Requirements HTA125A 120V 60 Hz 3 1A 260 watts Full Rated Output Idle 45W HTA250A 120V 60 Hz 5 5A 520 watts Full Rated Output Idle 60W Thermal Emissions full power HTA125A 426 9 BTU hr HTA250A 939 2 BTU hr Overload Protection Electronic overload protection Electrical HTA125A 4A Slo Blo Fuse HTA250A 7A Slo Blo Fuse Thermal Thermosta...

Страница 8: ...ESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED AND EXCLUDED TO THE MAXIMUM EXTENT ALLOWABLE BY LAW Bogen s liability arising out of the manufacture sale or supplying of products or their use or disposition whether based upon warranty contract tort or otherwise shall be limited to the price of the product IN NO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDIN...

Отзывы: