background image

50 Spring Street, Ramsey, New Jersey 07446, U.S.A.

Tel. 201-934-8500 • Fax: 201-934-9832

www.bogen.com

Limited Warranty; Exclusion of Certain Damages

The Bogen 

Classic Series Amplifiers

are warranted to be free from defects in material or workmanship for two (

2

)

years from the date of sale to the original purchaser. Any part of the product covered by this warranty that, with normal
installation and use, becomes defective will be repaired or replaced by Bogen, at our option, provided the product is
shipped insured and prepaid to: Bogen Factory Service Department, 50 Spring Street, Ramsey, NJ 07446, USA. The
product will be returned to you freight prepaid. This warranty does not extend to any of our products that have been
subjected to abuse, misuse, improper storage, neglect, accident, improper installation or have been modified or repaired
or altered in any manner whatsoever, or where the serial number or date code has been removed or defaced.

THE FOREGOING LIMITED WARRANTY IS BOGEN’S SOLE AND EXCLUSIVE WARRANTY AND
THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY. BOGEN MAKES NO OTHER WARRANTIES
OF ANY KIND, EITHER EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MER-
CHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED AND
EXCLUDED TO THE MAXIMUM EXTENT ALLOWABLE BY LAW.

Bogen’s liability arising out of the manu-

facture, sale or supplying of products or their use or disposition, whether based upon warranty, contract, tort or other-
wise, shall be limited to the price of the product. 

IN NO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL,

INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, LOSS OF
PROFITS, LOSS OF DATA OR LOSS OF USE DAMAGES) ARISING OUT OF THE MANUFACTURE,
SALE OR SUPPLYING OF PRODUCTS, EVEN IF BOGEN HAS BEEN ADVISED OF THE POSSIBILITY
OF SUCH DAMAGES OR LOSSES.

Some States do not allow the exclusion or limitation of incidental or conse-

quential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights,
and you may also have other rights which vary from State to State.

7/22/2008

Содержание C10

Страница 1: ...Classic Series Public Address Amplifiers C10 C20 Models Installation and Use Manual 2009 Bogen Communications Inc All rights reserved Specifications subject to change without notice 54 5978 01C 1106 ...

Страница 2: ...o not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety I...

Страница 3: ...t Connections 5 Microphone Connections 5 Microphone Precedence 5 AUX 5 TEL 5 Output Connections 6 Speakers General 6 OPERATION 6 POWER 6 MIC1 MIC2 6 AUX 6 TEL 6 VOX SENS 6 Microphone Precedence 6 TREBLE 6 Overload Protection 6 ACCESSORIES 7 TECHNICAL SPECIFICATIONS 7 LIMITED WARRANTY Back Cover ...

Страница 4: ...m speakers and for 25 and 70 volt constant voltage systems An accessory transformer Bogen Model WMT1A can be installed to provide input and output matching to a telephone line The amplifiers operate from a 120 60Hz source A thermostat enclosed in the power transformer protects the unit against overloads The amplifier also accommodates a transformer balanced TEL page input with VOX detector for mut...

Страница 5: ... any signal source having a line level greater than 85mV output TEL A balanced isolating transformer input for a telephone line is provided A 600 ohm telephone line may be connected to the TEL terminals Rear Panel 1 Amplifier Output Screw terminal strip containing all available speaker outputs 2 Mute Input Screw terminal input for microphone precedence 3 MIC1 MIC2 Screw terminal input for Lo Z bal...

Страница 6: ...if the input is not used VOX SENS The VOX SENSitivity control should be set so that only the desired TEL signal is above the threshold level while noise and unwanted signal is below it When an input signal such as a voice is detected the AUX channel will be muted To adjust the sensitivity of the circuit 1 Rotate the control fully clockwise While making a page announcement and talking at a low leve...

Страница 7: ... Power Requirements 120V 60Hz C10 38W C20 50W Dimensions 11 3 8 W x 2 7 8 H x 7 3 8 D both models Shipping Weight C10 6 lb C20 6 lb Technical Specifications Accessories WMT1A Line Matching Transformer Hi Z 10k ohm primary impedance Lo Z 600 ohm secondary impedance balanced with center tap Matches high impedance unbalanced or low impedance balanced signals Jumper selection allows line level signal ...

Страница 8: ...ed THE FOREGOING LIMITED WARRANTY IS BOGEN S SOLE AND EXCLUSIVE WARRANTY AND THE PURCHASER S SOLE AND EXCLUSIVE REMEDY BOGEN MAKES NO OTHER WARRANTIES OF ANY KIND EITHER EXPRESS OR IMPLIED AND ALL IMPLIED WARRANTIES OF MER CHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED AND EXCLUDED TO THE MAXIMUM EXTENT ALLOWABLE BY LAW Bogen s liability arising out of the manu facture sale...

Отзывы: