Operation

Sleep Switch

The Black Max amplifier includes a sleep mode feature that greatly reduces
the power consumption of the amplifier after it has been idle (no audio
activity) for more than 3 minutes.  Any audio activity present at the input
will power up the amplifier instantaneously and noiselessly, so that there is
no loss of audio. The Sleep Switch is located on the rear of the unit. The
sleep feature is activated by setting the switch to the AUTO position.
Setting the switch to the OFF position will inhibit the amplifier from ever
entering sleep mode. 

Power Sequencing Switch

The setting of the Power Sequencing Switch on the rear of the Black Max
amplifier determines how the amplifier will power up. When the switch is
set to the OFF position, the amplifier will power up and down convention-
ally when the front Power Switch is turned ON and OFF.

To use the sequencing feature built into the amplifier, the Power
Sequencing Switch must be placed in the ON position on a slave amplifier.
The slave amplifier will now power up when it receives the proper trigger
through the terminal strip wiring (see 

Sequential Turn-On 

section for prop-

er wiring of the power sequencing terminal strip). With the Power
Sequencing Switch in the ON position, placing the front Power Switch in
the ON position will not result in the amplifier turning on. It will instead
remain in a standby state until triggered through the sequencing feature.

Power Status Indicator

A Power Status Indicator is provided on the rear of the amplifier. The Black
Max amplifier has different states of powering up, depending on whether
power sequencing is used or not. The Power Status Indicator provides 3
different status indications:

Not Lit -

Indicates that the unit is not plugged in or is not being supplied
AC power at the line cord.

Amber -

Indicates that the unit is in standby state where it is being sup-

plied with AC power at the line cord but it has either: 

1

) not

received the sequencing trigger that will allow it to change to
the fully-powered state if the Power Sequencing Switch is set
to ON, or 2) the front Power Switch has not been turned ON
if the Power Sequencing Switch is set to the OFF position.

Green -

Fully-powered, the unit has either: 

1

) received the sequencing

trigger if the Power Sequencing Switch is set to the ON posi-
tion, or 2) the unit’s front panel Power Switch has been turned
ON if the Power Sequencing Switch is set to the OFF position.

CH B Input Select Switch

Determines whether the amplifier's output channel 'B' sources its input
signal from "B BAL INPUT" or "A BAL INPUT" connectors.

Note: 

When set to "IN A", "B BAL INPUT" connector and CH B "Input

Sens" Switch are not active, but CH B level control and Low Cut Switch 
are active.

Input Sensitivity Switch

Each input has a user-selectable sensitivity switch. When operating
with standard line-level source equipment, the input should be set for

1

V.  When operating with low-level source equipment, the input

should be set for 0.

1

V.

9

Содержание Black Max X300

Страница 1: ...Black Max Amplifier X300 X450 X600 Models Installation and Use Manual 2005 Bogen Communications Inc All rights reserved 54 2063 01D 0910 ...

Страница 2: ...it into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufac turer 12 Unplug this apparatus during lightning storms or when unused for long periods of time 13 Refer ...

Страница 3: ...nical Components 4 Ventilation 5 Rack Mounting 5 Rear Rack Mounting 5 Table Mounting 5 CONNECTIONS 6 Speakers 6 Inputs 6 AC Power 6 SEQUENTIAL TURN ON 7 Sequential Turn On Operation 7 OPERATION 8 9 Front Controls Indicators 8 Rear Controls Indicators 8 TROUBLESHOOTING 10 SPECIFICATIONS 11 LIMITED WARRANTY EXCLUSION OF CERTAIN DAMAGES 12 ii ...

Страница 4: ...iii ...

Страница 5: ...ltage and thermal circuits A special Clip Limiting circuit continuously monitors the amount of distortion in the output signal and reduces input levels as the amplifier approaches clipping Back Slope AC Voltage Stabilization Bogen s unique voltage stabilization circuitry regulates the AC energy supplied from the power toroid This improves both system performance and reliability despite varying AC ...

Страница 6: ...minate amber when excessive signal levels or very low impedance output loads cause output distortion to exceed a few percent Under such conditions a built in Clip Limiting circuit activates and reduces input signal levels to protect both amplifier and speaker loads One for each channel 4 Power Switch Circuit Breaker Magnetic circuit breaker controls AC power to the amplifier 5 Fan Air Intake and G...

Страница 7: ...s maxi mum current requirements exceed the capacity of a typical 15A receptacle The 20A receptacle is a NEMA 5 20R style 8 AC Power Status Indicator Indicates the AC power status of the Black Max amplifier When the indicator is not lit no AC power is applied to the line cord When lit amber power is applied to the line cord but no sequential trigger has been received to place the amplifier into a f...

Страница 8: ... sinks Periodic clean ing should be done when there is a noticeable build up of dust on the filters To clean the filters remove them from the grilles and wash vacuum or tap them out Promptly replace them Caution The fan blades are accessible when the grille cover and filter are removed Be careful not to place your finger or other objects into the fan 3 Fan Grille To attach the fan grilles first sl...

Страница 9: ... ears are included with the amplifier to allow mount ing in 19 racks Attach the rack ears as shown in the Mechanical Components section If any feet have been attached to the bottom of the amplifier remove them Load the amplifier into the rack and secure it to the rack with appropriate hardware not included Rear Rack Mounting Optional accessory not included For greater rear support when rack mounti...

Страница 10: ...terminals of either output No damage will occur if this is done but the amplifier will go into protect mode and shut down the affected channel Inputs Balanced Input Connections Balanced input connections are used when the source device provides a balanced output signal signal and ground G This type of con nection is desirable when operating in electrically noisy environments where long input cable...

Страница 11: ...ting the switch to OFF this amplifier will turn on and off direct ly by its front Power Switch All other amplifiers in the chain MUST have their Power Sequencing switches in the ON position so that they respond to the sequencing signals All slave amplifiers MUST have their front Power Switch set to the ON position with the exception of the master amplifier To Begin the Power Up Sequence Turn on th...

Страница 12: ...re is signal at the output STATUS Illuminates in three different colors to indicate current opera tional status of the amplifier Green Indicates that the amplifier is operating normally Amber Indicates that the amplifier is in Sleep mode Red Indicates a fault condition and that the amplifier has disconnected the output load as a safety precaution Rear Controls Indicators Level Controls Use the rea...

Страница 13: ...te until triggered through the sequencing feature Power Status Indicator A Power Status Indicator is provided on the rear of the amplifier The Black Max amplifier has different states of powering up depending on whether power sequencing is used or not The Power Status Indicator provides 3 different status indications Not Lit Indicates that the unit is not plugged in or is not being supplied AC pow...

Страница 14: ...ormer or other EMI radiating devices Electrically noisy devices operating on the same AC circuit Poor equipment grounding Ensure that all AC safety grounds are connected Make sure that all components in audio chain are tied to the same ground NO SOUND NOISE HUM DISTORTED SOUND INTERMITTENT OPERATION Status LED is green Signal LED is off Level Controls turned down No signal from source CH B Input S...

Страница 15: ...ms 16 ohms Frequency Response 1 watt 20 Hz 20 kHz 0 25 dB Output Regulation 1 5 dB 70V Inputs 100k ohm electronically balanced 3 pin pluggable terminal strip Low Cut Filter 60 Hz 2nd order roll off switch defeatable per channel AC Input Voltage Range 95 130V AC 60 Hz AC Current Rating full power 20A 15A 12A AC Voltage 120V AC 60 Hz Indicators Status Limit Signal AC Power Status Rear Temperature Ra...

Страница 16: ...D WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PAR TICULAR PURPOSE ARE HEREBY DISCLAIMED AND EXCLUDED TO THE MAXIMUM EXTENT ALLOWABLE BY LAW Bogen s liability arising out of the manufacture sale or supplying of products or their use or disposition whether based upon warranty contract tort or otherwise shall be limited to the price of the product IN NO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL INCI...

Отзывы: