Operating instructions for S 40-3...S 150-3 series screw compressors
Page 15
Product description
2.1
Technical data
Part 2: Product description
2.1 Technical data
Technical data S 40-3...S 100-3, part 1
Type
S 40-3
S 50-3
S 60-3
S 61-3
S 75-3
S 100-3
Dimensions
- Height (silenced)
[inch]
57.0
57.0
57.0
57.2
57.2
57.2
- Height (super silenced)
[inch]
-
76.5
76.5
76.7
76.7
76.7
- Width (silenced/super silenced)
[inch]
63.6
63.6
63.6
80.5
80.5
80.5
– Depth
[inch]
38.9
38.9
38.9
41.9
41.9
41.9
Weight
– silenced
[lbs.]
1856
1858
2191
2601
2778
2994
– super silenced
[lbs.]
-
1924
2257
2712
2888
3104
Air
c
ool
in
g
Max. sound pressure level
[±3 dB(A)]
– silenced / super silenced
[dB(A)]
64 / -
73 / 71
74 / 72
77 / 71
79 / 73
80 / 73
Measurement surface
– silenced / super silenced
[dB(A)]
15 / -
15 / 16
15 / 16
16 / 17
16 / 17
16 / 17
Sound power level
– silenced / super silenced
[dB(A)]
79 / -
88 / 87
89 / 88
93 / 88
95 / 90
96 / 90
Wa
te
r c
oo
lin
g
Max. sound pressure level
[±3 dB(A)]
– silenced / super silenced
[dB(A)]
63 / -
72 / 70
73 / 71
76 / 70
78 / 72
79 / 72
Measurement surface
– silenced / super silenced
[dB(A)]
15 / -
15 / 16
15 / 16
16 / 17
16 / 17
16 / 17
Sound power level
– silenced / super silenced
[dB(A)]
78 / -
87 / 86
88 / 87
92 / 87
94 / 89
95 / 89
Compressor
Max.final compression temperature
[°F]
+ 230
+ 230
+ 230
+ 230
+ 230
+ 230
Volume flow according to
ISO 1217 appendix C at:
– p
max
= 100 psig
[cfm]
192.24
244.83
269.10
286.76
352.02
474.70
– p
max
= 115 psig
[cfm]
183.97
228.81
257.76
272.95
336.86
451.97
– p
max
= 125 psig
[cfm]
183.97
228.81
257.76
272.95
336.86
451.97
– p
max
= 150 psig
[cfm]
167.02
204.80
230.57
240.46
298.02
386.64
– p
max
= 190 psig
[cfm]
140.18
175.14
195.97
207.98
256.35
335.80
Drive motor
Rated power
[Hp]
40
50
60
60
74
101
Rated speed
– 60 Hz
[rpm]
3600
3600
3600
3600
3600
3600
Protection type
IP
TEFC
TEFC
TEFC
TEFC
TEFC
TEFC
ISO class
F
F
F
F
F
F
Electrical connection
Mains voltage compressor
1)
[V]
1)
Standard equipment. Mains voltages and frequencies are specified on a plate in the switch cabinet.
208 / 230 /
460 / 575
230 / 460 / 575
460 / 575
460 / 575
460 / 575
460 / 575
Frequency
1)
[Hz]
60
60
60
60
60
60
Fuse protection for 208 V
2)
[A]
150
-
-
-
-
-
Fuse protection for 230 V
2)
[A]
2)
Use fuse RK 5 only. The fuse values change in the case of other mains voltages and frequencies.
125
175
-
-
-
-
Fuse protection for 460 V
2)
[A]
60
70
90
90
125
150
Fuse protection for 575 V
2)
[A]
50
60
70
70
90
125