Barber Colman 7SC Programming Procedure
To switch display from F° to C°, see instructions at the end of this section.
1)
Remove the instrument from its case and put the V101 switch in the open
position. The V101 switch is located on the bottom of the unit. Verify that
jumper J106 is:
1-2
3-4
5-6
7-8
9-10
Open
Closed
Open
Open
Open
The J106 jumper is located on the top of the unit. Insert the instrument back
into the case.
2)
Turn on the power to the unit by switching the fan on. The display should
show COnF; press the FUNC key to step through the configuration parameters.
3)
The following configuration parameters should be entered/verified (Use the
Up/Down keys to change the values if necessary):
Ser1
0FF
P7
--
Ser2
1
P8
--
Ser3
19.20
P9
AL1.P
Ser4
7E
P10
H.A.
P11
nonE
P1
22
P12
--
P2
--
P13
--
P3
0
P14
--
P4
600
P15
--
P5
rEU
P16
0
P6
4-20
P17
SFt.A (3111)
4)
The Display should now show: -.-.-.-. Press the Up/Down keys to display
262, and then press the FUNC key to access the advanced configuration.
5)
The following advanced configuration parameters should be entered/verified
(Use the Up/Down keys to change the values if necessary):
P18
norL
P32
1.0
P19
norL
P33
0.20
P20
--
P34
0FF
Содержание XLT TS Series
Страница 2: ...2 XLT TS Series Service Manual ...
Страница 14: ...14 XLT TS Series Service Manual Figure 4 Temperature Control Figure 5 Burner Control and Signal Conditioner ...
Страница 35: ...XLT TS Series Service Manual 35 Electrical Schematics ...
Страница 36: ...36 XLT TS Series Service Manual ...
Страница 37: ...XLT TS Series Service Manual 37 ...