9. 

Warranty 

When used in laboratory conditions and according to these operating instructions, 
Boekel warrants this product to be free of defective material and workmanship for a 
period of two years from the date of manufacture.  The liability of Boekel for any 
defective equipment during the warranty period shall be limited to the repair of 
such equipment or replacement thereof without charge for parts or labor. 

 

10.  Service 

It is required to obtain a Returned Material Authorization (RMA) number before any 
Boekel products are returned for any reason.  A Decontamination Certificate must 
be completed, signed by the user, and returned to Boekel Scientific prior to 
receiving the RMA number.  Please be sure to mark the outside of the returned 
goods package with this RMA number to ensure prompt handling. 

 
 
 

Boekel Scientific 
855 Pennsylvania Boulevard 
Feasterville, PA  19053 
Phone: (215) 396-8200 or (800) 336-6929 
Fax: (215) 396-8264 
e-mail: 

 

Fuse
Drawer

Содержание 133000

Страница 1: ...Boekel Incubator Models 133000 133000 2 133000S Operating Instructions N2400181 Rev 1 05 11...

Страница 2: ...r Lamps see Figure below 4 4 2 Setting the Temperature 5 4 3 Operating the Incubator 5 5 Accessories 5 5 1 Removable Shelf Catalog Number C1902053 5 5 2 Shelf Bracket Catalog Number A1903208 5 6 Fault...

Страница 3: ...ety ground terminal Before moving disconnect at the power supply socket Do not remove the plug from the rear of the unit Do not check the temperature by touch but instead use the temperature display T...

Страница 4: ...all shipping damage to the carrier immediately Shipping damage is covered by the carrier and repair replacement for shipping damages must be coordinated through the carrier Complete and return the Wa...

Страница 5: ...er temperature in degrees Celsius The heater lamp indicated when the heater is operating The temperature adjust knob is used to control the chamber temperature Temperature Adjust Knob Power Switch O I...

Страница 6: ...ff O position If the temperature adjust knob is not moved when the incubator is powered down the incubator will return to its previously set temperature upon restart 5 Accessories 5 1 Removable Shelf...

Страница 7: ...xamined or supplied by Boekel or our agent 8 1 Cleaning Disengage power cord prior to cleaning If a spill occurs use appropriate clean up procedures as required for radiation or biohazard control The...

Страница 8: ...ithout charge for parts or labor 10 Service It is required to obtain a Returned Material Authorization RMA number before any Boekel products are returned for any reason A Decontamination Certificate m...

Отзывы: