background image

2015/2/2 V1.1+V1.1 

25 

 

During fitness, if there is no wireless signal detected, windows will show "NO 

PULSE" words. If the time is up to 60 seconds, it will enter PAUSE mode. 

 

When PRM is lower than 40, program windows will show figure

RPM↑

  and enter 

PAUSE mode after 5 seconds. 

 

HR CONTROL mode only can be used with wireless pulse and the hand grip pulse 

is no function under this mode. 

 

During program working, data windows will show below information

default figure 

is Level 1, press Up

Down Key can't modify it. 

4.4.6.  WATT MODE

it is WATT CONTROL MODE 

1.  Under start/steady window, press WATT, program windows will show

WATT

,Data 

windows moves left and show words

PRESS ENTER TO BEGIN PROFILE.

 

2.  Press ENTER to modify Target WATT. Data windows moves left and show words

ENTER WATT <25-400>

, USER can input number 0~9 to input Target WATT, Data 

windows will show

WATTS=                  xxx

  and flash the input value. Press the 

number key for modify must be 2~3 numbers(range is 25 ~ 400). Unreasonable value 

will auto change to show min or max value, input the reasonable value and press 

ENTER to confirm and store it. 

3.  Press ENTER for time modify, data windows will show words

ENTER TIME <10 - 60 > 

MINUTOS

, (range is10 ~ 60). Program windows show default value

10

  and flash 

the value. Press number 0~9 for modify and you must input 2 numbers(range is 10 ~ 

60). Unreasonable value will auto display default value, input the reasonable value and 

press ENTER to confirm the value and start program. 

4.  After finishing the set of last item's time, press Enter Key and all value start accounting. 

The default resistance value is Level 1 and it will change once per minute. When PRM 

is lower than 40, program windows will show figure

RPM↑

  and enter PAUSE mode 

after 5 seconds. 

5.  When program finishing or working, press STOP Key and program windows will auto 

show original Profile figure, data windows will show below training accounting items for 

2 seconds by turns for twice, then program will back to start/steady condition. 

Содержание Vertex R22.1

Страница 1: ...R22 1 RECUMBENT ASSEMBLE INSTRUCTION...

Страница 2: ...frame 1 H Computer decorative cover front 1 B Control tube 1 I Stuff holder 1 C Computer 1 J Flask holder 1 D Seat 1 K Lower seat cover 1 E Handrail tube 1 L Screw head cover 2 F Control tube decorat...

Страница 3: ...with inner toothed washer 4 K05 Truss cross self tapping screw 4x12 1 K16 Truss cross self tapping screw 4x12 stainless steel 1 K06 Truss cross screw M5xP0 8x10 4 K17 Cable transferring head_PAL M to...

Страница 4: ...2 V1 1 V1 1 3 3 ASSEMBLE STEPS STEP 1 ASSEMBLE FRAME AND CONTROL TUBE Make wire of frame A through control tube B and tighten control tube B on frame A with cks hex screw K01 spring washer K02 and was...

Страница 5: ...hten control tube decorative cover F with truss cross screw K04 and truss cross self tapping screw K04 as figure showing then cover screw head cover L Lower control wire Network connecting wire lower...

Страница 6: ...be upon you to avoid the hurt that hitting on the tube When assemble please aim at the hole and confirm the way of computer The wires matched with computer must match with computer s hole to avoid bre...

Страница 7: ...r decorative cover front H on control tube with truss cross screw K19 as below figure showing and fix the stuff holder I with truss cross self tapping screw K20 then tighten flask holder J on control...

Страница 8: ...2015 2 2 V1 1 V1 1 7 STEP 5 ASSEMBLE HANDRAIL AND SEAT Tighten seat D and handrail tube E with stainless steel cks hex screw K09 spring washer K10 washer K11...

Страница 9: ...andle bar into the socket of frame slipping rail then tighten seat D with stainless steel cks hex screw K12 spring washer K13 washer K14 as figure showing Caution When assemble it need two or more tha...

Страница 10: ...SEMBLE LOWER SEAT COVER AND FRAME Tighten lower seat cover K with stainless steel round head cross s crew with inner toothed washer K15 and truss cross self tapping screw K16 washer K21 as figure show...

Страница 11: ...dows will show words SELECT PROGRAM OR QUICK START The word will be different by the different languages 2 Sleep Mode Under start steady condition if there is no RPM signal input within 30 seconds bef...

Страница 12: ...TT program windows directly 10 TEST this key is program control s instant key press this key can enter TEST program windows directly 11 P1 this key is program control s instant key press this key can...

Страница 13: ...how LEVEL KMH TIME CAL 1s and show value 10 seconds Imperial MLH show LEVEL RPM DIST WAT 1s and show value 10 seconds then show LEVEL MLH TIME CAL 1s and show value 10 seconds 3 When program finish da...

Страница 14: ...0 0 CALORIES BURNT moving words shown first and then show KCAL 0 0 AVERAGE WATTS moving words shown first and then show WATTS 0 0 AVERAGE METS moving words shown first and then show METS 0 0 4 4 2 P 1...

Страница 15: ...input training time by pressing number 0 9 then press Enter key store and start the program If you want to modify the set value please press CLEAR key 5 During program working user can press LEVEL LE...

Страница 16: ...hen show KMH 0 0 CALORIES BURNT moving words shown first and then show KCAL 0 0 AVERAGE WATTS moving words shown first and then show WATTS 0 0 AVERAGE METS moving words shown first and then show METS...

Страница 17: ...NTER WEIGHT 30 199 KG or show ENTER WEIGHT 70 440 LBS words USER can use number key 0 9 to input weight program windows will flash and show default value 30 Press number key for modify must input 2 3...

Страница 18: ...and show value for 10 seconds imperial MLH show LEVEL RPM DIST WAT first for 1s and show value for 10 seconds then show LEVEL MLH TIME CAL first for 1s and show value for 10 seconds 8 When program fi...

Страница 19: ...and then show MLH 0 0 CALORIES BURNT moving words shown first and then show KCAL 0 0 AVERAGE WATTS moving words shown first and then show WATTS 0 0 AVERAGE METS moving words shown first and then show...

Страница 20: ...e time is clockwise for 10 seconds the default resistance value is level 1 When RPM is not enough program windows will show figure RPM and enter PAUSE mode after 5 seconds 3 During program working pro...

Страница 21: ...show value for 10 seconds then show LEVEL MLH TIME CAL first for 1s and show value for 10 seconds 6 When program finished data windows will show below information metric KMH EXERCISE TIME moving words...

Страница 22: ...nd then show MLH 0 0 CALORIES BURNT moving words shown first and then show KCAL 0 0 AVERAGE WATTS moving words shown first and then show WATTS 0 0 AVERAGE METS moving words shown first and then show M...

Страница 23: ...time set at this time program windows will flash and show training time s default value 10 data windows will show ENTER TIME 10 60 MINUTES USER can input number 0 9 to set training time When the inpu...

Страница 24: ...00 DISTANCE COVERED moving words shown first and then show KM 0 0 AVERAGE SPEED moving words shown first and then show KMH 0 0 CALORIES BURNT moving words shown first and then show KCAL 0 0 AVERAGE W...

Страница 25: ...s condition program will contrast the actual HR value with the set HR value the judge method as below When actual HR value set HR value for 15 WATT will auto increase 20 it can up to 400WATT When actu...

Страница 26: ...e Press the number key for modify must be 2 3 numbers range is 25 400 Unreasonable value will auto change to show min or max value input the reasonable value and press ENTER to confirm and store it 3...

Страница 27: ...ords shown first and then show HHMMSS 0 00 00 DISTANCE COVERED moving words shown first and then show KM 0 0 AVERAGE SPEED moving words shown first and then show KMH 0 0 CALORIES BURNT moving words sh...

Страница 28: ...ll auto increase 3 the max value can up to LEVEL 40 If target WATT value actual WATT target WATT for 50 during fitness and LEVEL will auto increase 2 the max value can up to LEVEL 40 If target WATT va...

Страница 29: ...value is 30 input the value If you press number key for modify and you must input 2 3 numbers range is 30 199 For the unreasonable value systems will auto show max or min value Press the reasonable va...

Страница 30: ...program will back to start steady condition 8 During program working data windows will show below information metric KMH show LEVEL RPM DIST WAT first for 1s and show value for 10 seconds then show L...

Страница 31: ...METS 0 0 imperial MLH EXERCISE TIME moving words shown first and then show HHMMSS 0 00 00 DISTANCE COVERED moving words shown first and then show ML 0 0 AVERAGE SPEED moving words shown first and then...

Страница 32: ...2015 2 2 V1 1 V1 1 31 5 PROFILE FIGURE 5 1 P 1 FIGURE PROGRAM 1 PROFILE PROGRAM 2 PROFILE PROGRAM 3 PROFILE...

Страница 33: ...2015 2 2 V1 1 V1 1 32 5 2 P 2 FIGURE INTERVAL 1 PROGRAM INTERVAL 2 PROGRAM INTERVAL 3 PROGRAM...

Страница 34: ...2015 2 2 V1 1 V1 1 33 5 3 TEST FIGURE FITNESS TEST TEST MALE TEST FEMALE 5 4 HRC FIGURE HRC 5 5 WATT FIGURE WATT CONTROL...

Страница 35: ...2015 2 2 V1 1 V1 1 34...