37
FRACTURES IN THE CABLE COVER
Casing can crack or fracture under strains during use. Any crack in the casing merits cable replacement
even if no wire rope is exposed.
This cable needs to be replaced as soon as possible.
A TEAR, TWISTING/BINDING IN THE
CABLE COVER
Inspect casing to ensure wire rope is not tearing, twisting, or binding within and coil causing bulge to
appear. Cable should retain same outside diameter throughout.
This cable needs to be replaced as soon as possible.
STRETCHED, FRAYED OR FLATTENED
CABLE COVERING
Any exposed wire rope protruding through the casing or at either end, has lost its structural integrity.
Section of cable is compressed and will not retain its shape (outside diameter).
STOP USING THE MACHINE: This cable needs to be replaced immediately.
A BREAK OR PERMANENTLY BEND IN
THE CABLE
Cable has a kink and prohibits cable from lying straight. Wire rope may be unraveling beneath the casing,
causing a compromise of its structural integrity.
STOP USING THE MACHINE: This cable needs to be replaced immediately.
CABLE END SEPARATING OR
SLIPPING OUT
Watch for component end of cable to pull away from cable assembly and look for exposed wire rope.
STOP USING THE MACHINE: This cable needs to be replaced immediately.
S
TRENGTH
C
ABLE
W
EAR
I
NDICATORS