background image

 

 

 

METAL

 

PRODUCT WATER FAUCET INSTALLATION AND SYSTEM CONNECTIONS

 

 

Install faucet on flat surface at least 2" in diameter.  Unused 1-1/4" hole is ideal.  

Steps unique to a specific configuration are so noted.  All other steps are common to either configuration.

 

 

New Faucet Installation

 

Refer to Faucet Site Preparation, Page 5.  

 

Replacement Faucet Installation

 

Verify size of existing hole is 1 1/4".  

 

NOTE:

  Item callouts refer to Page 7, Figure 7 unless 

noted otherwise. 

 

1. 

Air Gap Only: 

Verify faucet body, metal base 

washer, and rubber base washer are in place above 
sink (Items 1, 3, and 2). 

 

Non-Air Gap Only: 

Verify faucet body, metal base 

washer, and rubber base washer are in place above 
sink (Items 1, 3, and 2). 

 

2. 

CAUTION:

  Flow Restrictor (FLR) is installed inside 

 

the 1/4” red tubing on the end with the label. DO NOT 
TRIM THE END OF THE 1/4" FLR 
RED TUBING THAT INCLUDES  
THE LABEL (See Figure 8.A/B). 

 

 

Air Gap Only: 

Install 3/8” red tubing from  

 

Installation Kit onto larger hose barb as shown in  

 

Figure 7. 

 

3. 

Air Gap Only: 

Connect the 1/4” FLR red  

tubing end with FLR label between the  
module red collet near symbol shown  
and the faucet:

 

 

 

a. 

Air Gap Only:

  Insert the 3/8” red tube into the 

mounting hole. 

 

b. 

Air Gap Only:

  Insert the 1/4" FLR red tubing  

 

 

upwards through mounting hole. 

 

c. 

Air Gap Only:

  Position module in desired 

location.  Trim the end of FLR tubing without label 
to desired length.  Attach FLR tubing onto smaller 
hose barb as shown in Figure 7. 

 

4.  Lower faucet into mounting hole and place 
 

faucet over hole. 

 

 

5. 

Air Gap Only: 

Install slotted washer, spacer, faucet 

washer, and nut onto faucet nipple below sink and 
snug them up (Items 4, 5, 6, and 7).  Be sure to 
properly align faucet before tightening.  Do not over 
tighten. 

 

 

Non-Air Gap Only: 

Install locating washer, faucet 

washer and nut (Items 4A, 6, and 7) onto faucet 
nipple below sink and snug them up.  Be sure to align 
faucet properly before tightening.  Do not over tighten.  

 

6.  Install faucet connector (Item 8), packaged with 

faucet, onto faucet nipple.  Install 3/8” blue tube into 
faucet connector. 

 

7.  Trim 3/8” blue tube to desired length. Install  

3/8” blue tube into 3/8” blue collet located on  
side of module near symbol as shown. 

 
 

 

8. 

CAUTION:

  Red 3/8" tube connecting product water  

 

faucet to drain saddle must run vertically (or as  

 

closely as possible) with no sharp bends or loops  

 

(See Page 4, Figure 4). 

 

Connect loose ends of tubing as follows: 

 

a. 

Non-Air Gap Only:

  Connect 1/4" FLR red tubing 

       to 1/4" drain saddle using compression nut. 

 

b. 

Air Gap Only:

  Connect 3/8” red tubing to  

 

 

3/8" on drain saddle using compression nut. 

Refer to steps 2-4 in Polymer Tank Assembly for use 
of compression nuts. 

 

Storage Tank Connection - Metal Tank Assembly 

 

NOTE:

  The following instructions refer to Page IV,  

Figure 1.B, Items 2 & 3. 

NOTE:

  Refer to Page 2, Inter-Component Connections  

for instructions on how to install tubing. 

 

1.  Install ball valve (located inside of master pack box) 

onto the 1/4” storage tank nipple.  Use thread sealing 
tape to seal threads between ball valve and nipple.   

2.   Connect 3/8” white tubing between module  

(near symbol as shown) and storage tank  
shut-off valve.   

3.  The basic installation is complete and  

system is ready for activation (see Page 9). 

 

NOTE

: With the storage tank empty, ensure the air-cell 

pre-charge is set to manufacturer’s instructions marked 
on tank. Use a hand power air pump to increase, if 
necessary. 
 

WARNING

: Never use an air compressor to fill air cell of 

a reverse osmosis system storage tank. Damage to the 
tank and/or air cell can occur. 

 

NOTE

: Optional stem elbows have been  

supplied to allow installations with limited  
space. Connect the stem elbow into the  
inlet, faucet, tank and drain parts as  
required before connecting tubing.

Содержание BG-Pure

Страница 1: ...BG Pure OWNER S GUIDE ADVANCED REVERSE OSMOSIS WATER FILTER SYSTEM This model is tested and certified by WQA against NSF ANSI 58 for the reduction of TDS 4VTFC25G PB Model WI BG PURE ...

Страница 2: ...owing information and retain for reference Model Number WI BG PURE Serial Number _____________________________________ Date Purchased ____________________________________ Date Installed ______________________________________ ...

Страница 3: ...r keep a container of RO water in the fridge to enjoy the clean fresh taste of purified water Alternatively take it directly from the faucet dispenser o Ice Cubes use RO water to fill ice cube trays Ice cubes made from RO water are typically clearer and better tasting than ice made from non filtered tap water o Automatic Ice Makers a water line from the RO system can be plumbed to refrigerators wi...

Страница 4: ... Cl2 2 0 Turbidity 1 0 NTU Nephelometric Turbidity Unit Silt Density Index Value stated in SDI units Maximum SDI 4 0 NOTES 1 TFC refers to reverse osmosis membranes constructed from a THIN FILM COMPOSITE 2 The daily production rate is the volume of product water produced by the system per day and is determined by testing in accordance with the procedure outlined in NSF ANSI Standard 58 3 System s ...

Страница 5: ...40600040 n s not shown PRODUCT WATER FAUCETS Item Description Part No 7 8 Chrome Plated Metal Air Gap Connector Faucet 3 8 x 7 16 92192 Fig 7 92407 INSTALLATION KIT 9 10 11 12 13 14 n s n s n s Complete Kit Supply Valve Saddle Tapping Drain Clamp Saddle Clamp Air Gap 3 8 Tubing 3 8 Red Tubing 3 8 Blue Tubing 3 8 White Tubing 1 4 White Screw Mounting Bracket 2 each Elbow Stem 3 8 2 each Elbow Stem ...

Страница 6: ...GENERAL INFORMATION PRODUCT WATER STORAGE TANK PRODUCT WATER STORAGE TANK Item Description Part No 1 2 Storage Tank Assembly Metal Ball Valve 3 8 92342 92294 33503601 Figure 1 B Product Water Storage Tank ...

Страница 7: ...e Specific requirements are detailed in Table 3 COMPONENT LOCATION REQUIREMENTS Table 3 PRODUCT WATER FAUCET Faucet may be installed in any convenient location Make sure underside of location is free of obstructions REVERSE OSMOSIS MODULE Module may be installed under sink or in any convenient location within 15 feet of source water supply and faucet STORAGE TANK Tank may be placed in any space wi...

Страница 8: ...ssed at any time the most accurate readings are obtained when the system is making water for at least 10 minutes INTER COMPONENT CONNECTIONS Connections between cold water supply line Body Glove RO Module storage tank product water faucet and drain line are accomplished using plastic tubing and push together quick connect type fittings PLASTIC TUBING 1 Cut tube ends square and straight Do not defo...

Страница 9: ...ng compression fitting a Slide nut and sleeve onto tubing in that order b Install insert into plastic tubing c Install tube with insert and sleeve into valve body d Thread compression nut onto valve body tighten 5 Turn saddle tapping valve handle clockwise until it is firmly seated and piercing lance is fully extended 6 CAUTION Supply line is pierced and valve is closed Do not open valve until sys...

Страница 10: ... P S trap between trap and sink Figure 4 Drain Hole Location and Installation Air Gap Faucet NOTE See Page III Figure 1 A for connection to drain for Non Air Gap Faucet 1 Select a location for drain hole based on type of sink and orientation of drain line Figure 4 2 Position drain outlet saddle Figure 5 Item 1 on drainpipe Allow adequate space for drilling operation 3 Tighten saddle bolts evenly o...

Страница 11: ...ure pilot guide is inserted tightly Insert pilot guide into pilot hole Push down gently on drill motor to apply light pressure to porcelain surface Start drill motor turning as slowly as possible After initial cut has started motor speed may be gradually increased The cut may require three to four minutes to complete Going faster could result in excessive chipping Be sure a complete ring has been ...

Страница 12: ...ng washer faucet washer and nut Items 4A 6 and 7 onto faucet nipple below sink and snug them up Be sure to align faucet properly before tightening Do not over tighten 6 Install faucet connector Item 8 packaged with faucet onto faucet nipple Install 3 8 blue tube into faucet connector 7 Trim 3 8 blue tube to desired length Install 3 8 blue tube into 3 8 blue collet located on side of module near sy...

Страница 13: ...01 or 92192 1 2 3 4 4A 5 6 7 8 Body Faucet Faucet Base Washer Rubber Faucet Base Washer Metal Washer Slotted Air Gap Slot Shape may vary Washer Locating Non Air Gap Replaces Items 4 and 5 not shown Spacer Faucet Air Gap Washer Faucet Nut Faucet Connector Faucet 3 8 x 7 16 Figure 7 Chrome Plated Metal Product Water Faucet Assembly ...

Страница 14: ...fold Assembled Cartridge Sediment 5 micron Filter Membrane Thin Film Composite 25 GPD Yellow Casing Black Tape Cartridge Carbon AES 10 micron O Ring Filter Housing Housing Filter Circuit Board Battery 9 volt Elbow Stem 3 8 Elbow Stem 1 4 Kit O Rings Collets QC 3 8 Safety Clips Safety Clips 3 8 Note These parts are included with installation kit Includes Items 2 3 4 5 n s not shown 20500127 3270103...

Страница 15: ...connections for leaks and correct if necessary Icemaker Extra point of use Check connections on these supply lines for leaks 10 Allow storage tank to fill overnight 11 WARNING DO NOT USE THE FIRST FULL STORAGE TANK OF WATER Discard to drain first full tank of water by opening product water and extra point of use faucet until water flow stops then close faucet This will flush sanitizing solution fr...

Страница 16: ...water Inspect them for damage i e nicks scratches Replace damaged O rings 8 CAUTION Do not allow the Smartap Water Quality Monitor electronics wiring or connectors to get wet Clean filter housings and manifold ports inside and outside with washcloth and cleaning solution Do not use abrasive materials 9 Rinse manifold housings with clean potable water 10 Inspect manifold and filter housing O ring g...

Страница 17: ...Remove battery by sliding it out of its holder 26 Slide new battery into its holder 27 CAUTION Verify battery connector alignment before making connection Figure 9 Connect battery by pressing clip onto battery terminals NOTE Release button immediately after light illuminates Test is to confirm battery connection not water quality 28 Test battery connection by activating monitor Press push button I...

Страница 18: ...actory drain storage tank sanitize system and replace membrane Drain storage tank and let it refill overnight LEAKAGE AND NOISE Symptom Probable Cause Solution Leak at fitting Tubing not pushed completely into fitting Defective tube Push tube into fitting past O ring seal Cut damaged area from tube or replace tube See Page 2 Figure 2 Leak at filter housings O ring has not seated properly O ring ha...

Страница 19: ...er system is altered by anyone other than Water Inc the warranty shall be void ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE LIMITED TO THE DURATION OF THE PERIOD SPECIFIED ABOVE FOR THE PARTS DESCRIBED IN THIS LIMITED WARRANTY Water Inc does not know the characteristics of your water supply The quality of water supplies ma...