User Manual for BCL-X Series Laser Machine
28
Picture A
Focus test is as shown in picture A:
First paste double-sided adhesive tape on outlet, press pulse button and check if the
facula is on the center of outlet. If not, please adjust 3 screws of laser head.
Attention:
Laser is invisible light but can do harm to human body. Please keep away from the laser
path when debugging. The operator must master the basic knowledge of laser machine.
4.2.3 Trial Processing
Put working material on the work table.
After laser path is adjusted, rotate screws of lens cone to the height of focusing clockwise.
After adjusting focus, lock screws of lens cone anticlockwise. The move the laser head to
specified location. At last open software, make or transfer pictures, set working
mode&speed&efficiency.
Then you can work the material after nominating downloaded files.
Take following picture as a reference.
V
Rotation axis processing
1. Electrical appliance installation
Front
Left
Right
Back
Adjusting
Lens cone fastening
nut
Focal length adjusting
tool
Red