37
2.2.2.2 Electrical installation - NTP PoE model
The paragraph numbers
x
indicated below refer to the figures above for model NTP 230V.
- With lighting option: pass the mains cable through the wall bracket then connect this cable to the
terminal block
1
in the terminals L-N-
dedicated to the lighting
,
- Attach this cable to the central bracket with a cable retainer
,
- Pass the Ethernet cable through the wall bracket (crimp and test the cable if necessary),
- Connect the Ethernet cable to the circuit board via the Ethernet port
2
,
- Connect the back-up battery cable (if there is one) to the circuit board
3
,
- Clean the seal and then apply silicone oil on it,
- Move the removed clock face closer and then reconnect the flat cable
4
that goes from
the circuit board to the movement
5
located on the disassembled clock face.
The clock face / flat
cable A corresponds to the disassembled face, the one that gives access to the circuit board
(grommet side).
- Limit the length of the cable by passing it through the cable clip in order to avoid shading in the
case of the lighting option (contact of the cable with the dial once the clock is closed),
PoE version circuit board with power supply module behind the Ethernet port
- Close the clock again by putting the disassembled clock face back in its original position,
- Tighten the four cover screws (1,2 Nm) on the reassembled clock face,
- Replace and tighten the air inlet screw (15 nm) located on the underside of the wall bracket.
EN