Steel frame Table form lift TL 1512
213300043
65
Malfunction
,
CODE*
Error message
Possible cause
Troubleshooting:
Repair by
NO1
“Floor” safety circuit
a) The Emergency Off
button was activated
b) The Emergency Off
button on one of the
loading point control
system was activated
c) The electrically
monitored enclosure
door is open
d) The blind plug for the
socket is missing
e) The blind plug of the
safety chain is missing
f) The “floor”safety
circuit is interrupted
a) Unlock button
a) Unlock button
c) Close electrically control
enclosure door
d) Plug in the blind plug for the
‘Operation’ socket
e) Plug in the blind plug for the
safety chain
f) Check all connections if
necessary repair broken wire
of trailing cable
a) US
a) US
c) US
c) US
e) US
f) TE
NO2
Excessive load
a) Lift capacity
exceeded
b) If using a 2-mast
system, load measuring
unit may be canted
a) Remove payload from lift
b) Vent system manually
a) US
b) LO
NO3
Safety brake
a) Do not reset the
switch of the safety
brake after safety test
b) Safety brake was
triggered during normal
operation
a) Reset safety brake switch
b) Inspect drive
safety brake
a) LO
b) TE
Содержание TL 1512
Страница 18: ...Steel frame Table form lift TL 1512 18 213300043 3 Design and function 3 1 Overview Fig 7 Overall view...
Страница 19: ...Steel frame Table form lift TL 1512 213300043 19 Fig 8 Top view 19...
Страница 78: ...Steel frame Table form lift TL 1512 78 213300043 8 3 1 Illustration of loading points...
Страница 113: ...Steel frame Table form lift TL 1512 213300043 113 17 Appendix 17 1 Lift truck data sheet EJB 213 EHW Table...
Страница 114: ...Steel frame Table form lift TL 1512 114 213300043...