Страница 1: ...1 Assembly and operation manual Nursing care bed floorline 9 5 80...

Страница 2: ...antee optimal lying comfort and allow professional care at the same time This product was designed with a focus on the elderly whose confi dence must be reinforced and whose life needs protection With...

Страница 3: ...e hand control 18 3 7 Hand control lock functions 20 3 8 Second controller optional as accessory 20 3 9 Rechargeable Battery optional as accessory 21 4 Assembly and operation 23 4 1 Technical data 23...

Страница 4: ...lled HomeCare bed 5 Home care nursing service 1 1 Intended purpose The nursing care bed is suitable for persons adults in need of care who are at least 146 cm tall The person s weight must not exceed...

Страница 5: ...and cost units include all physical or juridical persons who use the beds or have the beds used for medical pur poses The briefing on the use of the product shall generally be conducted by the operat...

Страница 6: ...f the person in need of care cannot operate the hand control safely due to cer tain disabilities if the person in need of care or the caregivers could be at risk due to those acci dental adjustments i...

Страница 7: ...he manufacturer 1 5 Requirements for the installation location The company Hermann Bock GmbH is not liable for damages which might arise from the daily usage on the floor To avoid floor indentations f...

Страница 8: ...and general type plate 1 Model designation 2 Manufacture date Day month and year 3 Serial number Order number running number 4 Mains voltage mains frequency and power input 5 Duty cycle 6 Drive protec...

Страница 9: ...po sed of as household waste Medical application part type B Use only in dry rooms Protection class II double insulation insulated for protection IPX4 Protection of electrical equipment against splash...

Страница 10: ...oltage DC motors 29 to 35V and con trolled with the smooth keys of the hand control ler The backrest can be adjusted electrically The leg part consists of a foot support that is divided into two parts...

Страница 11: ...d panel at the gripping groove 4 and slowly raise the side rail somewhat Now you can fully press the release button 5 and slowly lower the side rail Please observe Be sure to raise the side rail sligh...

Страница 12: ...oden side rail solo post in the middle Fig 3 Telescopic wooden side rail double post in the middle All dimensions in mm Depending on the length of the lying surface The single post at the head and leg...

Страница 13: ...en side rail two bars 91703 Fig 2 Telescopic wooden side rail solo post in the middle Wooden side rail two bars 91868 Fig 3 Telescopic wooden side rail double post in the middle Wooden side rail long...

Страница 14: ...s the thermal fuse immediately shuts off the power supply to the bed After a cooling time of approx one hour the power supply in the controller is automatically re stored 3 2 Caution Electric drive Th...

Страница 15: ...p only to a minimum degree under load and it is equipped with electronic performance monitoring The result is a constant voltage up to the maximum load no loss of speed and a high level of protection...

Страница 16: ...the controller sockets 3 4 5 and 6 The colour coding can be found in chapter 4 Assembly and operation A floor lighting can be connected to the connection socket for the hand control socket 2 which in...

Страница 17: ...N BUS connection which can also be used to connect a sensor pad for a bed off detection Further details can be found in the separately supplied assembly and operation manual of the Smart Care Control...

Страница 18: ...nance of the bed Thus a possible dis ruptive position of the hand control can be avoided by simply attaching it to any preferred spot on the bed Hazard note from Bock All drive components must not be...

Страница 19: ...37 5 cm exit position safety stop at 27 5 cm safety position 9 Reset It is absolutely necessary to carry out this work during initial commissioning and after disconnection from the power supply The re...

Страница 20: ...et 1 and the second controller in socket 2 are plugged into this second control box Sockets 3 4 and 5 remain unassigned and are equipped with a blind plug Hazard note from Bock Make sure that the cabl...

Страница 21: ...d controller These functions must be locked separately here 3 9 Rechargeable Battery optional as accessory The battery serves as a mains independent reset function No warranty shall be provided for th...

Страница 22: ...sively Then disconnect the battery from the controller and shut down the drive system Do not open or destroy the battery Do not expose the battery to heat or open fire Avoid storage in direct sunlight...

Страница 23: ...nuous Wood side rail kg 165 Lying surface kg 66 Wood end panel incl lift column kg 39 Continuous wood side rail kg set 12 5 Telescopic wood side rail kg set 18 Electric data Manufacturer Dewert Baumei...

Страница 24: ...tient s room or to allow access to the patient The nursing care bed is suitable for persons adults in need of care who are at least 146 cm tall The person s weight must not exceed 185 kg and must be o...

Страница 25: ...lug the end piece with the narrow intake in the extension slide on the foot side of the lying surface connect the supplied hexagon socket screws M8x25 and tighten firmly 2 Screw the galvanized angle b...

Страница 26: ...cable is also located Guide the cable of the lifting column from the foot part is through the still unused ca ble channel all the way to the controller Fix this cable at the angle bracket with a cable...

Страница 27: ...them together After all side guard rails are installed slide the end piece back and tighten the screws again Telescopic side protection Place the outer posts at the end of the lying sur face and the m...

Страница 28: ...table feet Move the bed to the lower position second safety stop and check whether there is still approx 5 mm of air left between the floor and the underside of the telescopic post Inserting the decor...

Страница 29: ...ing the telescopic split side rail on this nursing care beds four adjustable feet must be screwed under the lying surface to prevent the telescopic posts of the side rail from touching the floor The s...

Страница 30: ...ccessory and remove both attached aluminium caps Place the aluminium caps to the pull outs Push the foot end piece back again so that the longi tudinal frame and the part in position are aligned flush...

Страница 31: ...e moves the locking pin from the motor The motor is now separated from the back part and can be swivelled downwards Once the second person has left the danger zone the first person can lower gently th...

Страница 32: ...ccomplish this use your foot to move the locking lever on each castor downwards Make sure that the castors are parallel to the longitudinal axis of the bed This is important in the Trendelen burg and...

Страница 33: ...stop after a short time There is an obstruction in the adjustment range Remove obstruction The safe working load has been exceeded Reduce the load The drives stop after a longer adjustment time The a...

Страница 34: ...d of care who have a particular physique can only be achieved by means of custom built models With its customized models Hermann Bock GmbH enables customers to have their nursing care bed tailored to...

Страница 35: ...itives for the cleaning of the plastic elements should generally be sufficient For care of the plastic surfaces use a product that is specifically suitable for plastics Drive To prevent the intrusion...

Страница 36: ...excluded 2 Check all plug connections for correct position according to the instructions 3 Check the cables and electrical component parts for damage Should you detect any damage do not perform any c...

Страница 37: ...Contact discharge 8 kV Air discharge 2 kV 4kV 8kV 15kV Floors should be wood concrete or ceramic tile If floors are covered with synthetic mate rial the relative humidity should be at least 30 Electro...

Страница 38: ...e RF compliance level above the medizinisches Bett should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as reorienting or relocat...

Страница 39: ...rol and observance of the corresponding intervals for a fee The company Hermann Bock GmbH specifies an inspection interval which stipulates that a safety technical inspection is to be executed at leas...

Страница 40: ...r damages to the wooden parts visible Electrical components 9 Power cables connecting cables and plugs without cable breaks pressure and kinking points abrasions porous points and exposed wires 10 Str...