31
In maintenance of the unit, take into
consideration the rate of use and the
environment it is used in. When the unit is used
properly and serviced regularly, you will avoid
unnecessary disturbances in use and production.
7.1 Daily Maintenance
Perform the following maintenance daily:
• Clean electrode holder and TIG torch's gas
nozzle. Replace damaged or worn parts.
• Check TIG torch's electrode. Replace or
sharpen, if necessary.
• Check tightness of welding and earth cable
connections.
• Check condition of mains and welding cables
and replace damaged cables.
• See that there is enough space in front of and
back of the unit for ventilation.
7.2 Troubleshooting
Main switch signal light is not lit.
Unit does not get electricity.
• Check mains fuses and replace if necessary.
• Check mains cable and plug, replace damaged
parts.
Unit does not weld well.
Arc is uneven and goes off. Electrode gets stuck
in weld pool.
• Check welding settings and adjust when
necessary.
• Check that earth clamp is properly fixed and
that contact surface is clean and the cable is
undamaged.
Signal light for overheating is lit.
The unit has overheated. See 5.0 Operating
Functions
• Check that there is ample space in front of
and back of the unit for ventilation.
• Check welding settings. See 5.1 Welding
Selections
If problems in use are not solved with above
mentioned measures, please contact your local
BOC representative.
7.0 Periodic Maintenance
Содержание Smootharc MMA 130
Страница 1: ...Smootharc MMA 130 O P E R AT I N G M A N U A L...
Страница 34: ...34...
Страница 35: ...35...