BOC BASELINE C106/1 Скачать руководство пользователя страница 7

7

BASELINE

®

 cylinder and secondary pressure regulators

9. Shutting down operations.

9.1 Cylinder regulator

For short stops in extraction of gas it is sufficient to close the shut-off valve on the regulator. In the case of longer stops, the regulator has 
to have the pressure released by turning the hand-wheel anti-clockwise. For safety reasons close the cylinder valve.

Caution

When dismantling as a general rule note: release pressure from regulator and tubing by venting the gas in a 
safe manner, the pointers of the inlet and outlet pressure gauges must indicate no internal pressure.

10. Maintenance and breakdowns.

10.1 Maintenance

The pressure control device should be examined regularly to make sure 
it is working correctly and to check for leaks.  Prior to carrying out main-
tenance and service work, inform the operating personnel and the users. 
For all service and maintenance work, shutoff and secure all power to 
associated operating equipment and secure the main switch to prevent it 
from being turned back on. Check fittings, which have come undone for 
correct positioning. After completing maintenance work, make sure that 
all safety devices and installations are functional.

Danger

For safety reasons, repairs and or maintenance 
work to the BASELINE

®

 pressure equipment, 

should only be carried out by BOC service compa-
nies or their authorized service personnel.

10.2 Malfunctions

By experience these regulators have a high level of reliabil-
ity. Should any of the following breakdowns occur despite 
this, exchange the regulator and have the defective equip-
ment repaired: 
–  Gas release at the outlet of the regulator when the hand-

wheel is completely closed. 

–  Display of increasing pressure on the outlet pressure gauge 

when the valve is closed or no gas is flowing. 

–  Gas release at the regulator cover. 
–  Gas release at a gasket. 
–  Too high pressure drop with normal flow. 
–  Gas release at the pressure relief valve. 
– Gas release at the pressure gauge. 
– Pointer of a pressure gauge does not return to „0“. 
– Faulty pressure display.

11. Return of pressure equipment.

Danger

Pressure equipment can only be returned with 
prior authorization. It must be completely de-
pressurized, drained and purged with an inert 
gas. The packaging must be sealed gas-tight 
to prevent contamination or exposure during 
transport.

Danger

Pay attention to local rules and legislation with regards to 
transport and storage of hazardous goods and materials.

12. Manufacture.

BOC reserves the right to make technical enhancements/changes to its products at 
any time, without notice. BOC reserves all rights.

Содержание BASELINE C106/1

Страница 1: ...User manual BASELINE BASELINE cylinder and secondary pressure regulators Models C106 1 C106X 1 C106 2 C106X 2 R104 1 Date 21 09 2007 A member of The Linde Group...

Страница 2: ...ure control devices Safety awareness among the users must be confirmed at regular intervals The responsibilities for user assembly start up and operation are to be clearly defined Personnel in trainin...

Страница 3: ...contained in this manual and any accompanying labels and or inserts provided that the same is properly operated under conditions of normal use and that regular periodic maintenance and service is per...

Страница 4: ...of the residue Do not contaminate the equipment with oily rags or grease Do not clean with solvents 3 Storage transport All pressure equipment must be clean and stored in a dust free dry and well seal...

Страница 5: ...ng fitting as the thread and the gasket could be damaged This can result in leakage uncontrolled release of gas or loss of the entire cylinder or gas sup ply contents Connecting to gas cylinder 1 Scre...

Страница 6: ...ppro priate protection measures are to be taken to protect personnel breathing apparatus eye protection and protective clothing as appropriate or required Maximum permis sible values of the concentrat...

Страница 7: ...l Danger For safety reasons repairs and or maintenance work to the BASELINE pressure equipment should only be carried out by BOC service compa nies or their authorized service personnel 10 2 Malfuncti...

Страница 8: ...Getting ahead through innovation A member of The Linde Group...

Отзывы: