Form
No.
1540-69
r9/29/17 ©
2017
Bobrick
Washroom
Equipment,
Inc. Printed
in
U.S.A.
Page 9
64''
(163cm)
18''
(46cm)
64''
(163cm)
18''
(46cm)
12''
(31cm)
Panel Centerline
6''
(15cm)
70''
(180cm)
52''
(132cm)
Finish Face
of Floor
18''
(46cm)
CL
CL
23''
(58cm)
23''
(58cm)
CL
82-5/16''
(209cm)
Finish Face
of Floor
CHROME HARDW
ARE
1. Place adjustable supports in position for each panel to
hold them 12" (305mm) above the floor.
2. Place panels on the supports and into their respective
wall brackets. Do not secure panels to wall brackets at
this time.
Fig. 4: Panel and Adjustable Supports.
Fig. 5a: Floor-Anchored (shown) or
Ceiling-Hung Bracket Placement.
Fig. 5b: Overhead-Braced Bracket
Placement.
CAUTION: Panel centerline is not always on the stile centerline. Refer to Bobrick Layout Sheets for panel offsets.
A. Measure and mark the centerlines for two (2) U-brackets per stile.
B. Using U-bracket as a template, mark the location of all mounting holes. Use a 3/16" (5mm) drill bit for 5/8" (16mm)
deep pilot holes. Caution: Do not drill through the stile.
C. Secure U-brackets with #14 x 5/8" (6.4 x 16mm) screws.
D. Alcove in-line stile and panel attachment. (Fig 5b Alcove in-line stile) Use three (3) flat plates on one side of stile,
inside stall. Attach flat plate using 15/16" (25mm) shoulder screws and 5/8" barrel nuts.
For Panel to Stile
STEP 4
POSITION PANELS
INSTALL STILE-TO-PANEL BRACKETS
STEP 5
For In-Line Stile and Panel