Safety Information  

 

 

IMPORTANT SAFETY INFORMATION 

Read Information

 — All the safety and operating information should be read before the amplifier 

is plugged in. 

Follow Information

 — All operating and use information should be followed. 

Retain Information

 — Retain the safety and operating information for future reference. 

Heed Warnings 

— All warnings on the amplifier & in the operating instructions should be heeded. 

Ventilation

 — The amplifier should be situated so that its location or position does not interfere 

with its proper ventilation.  The amplifier should never be placed near or over a radiator or heat 
register.  The amplifier should not be placed in a built-in installation such as a bookcase or cabinet 
that may impede the flow of air through the ventilation openings. Do not place this amplifier 
directly on carpeted floors. 
 

Non-Use Periods

 — Amplifiers that are left unattended should be turned off via the rear panel 

switch to extend the life of the tubes and conserve energy. 

Grounding or Polarization

 — Do not defeat the safety purpose of the polarized or grounding-type 

plug.  A polarized plug has two blades with one blade wider than the other blade.  A grounding 
type plug has two blades and a third grounding prong.  The polarized wide blade and the third 
prong are provided for your safety.  If the provided plug does not fit your outlet, consult an 
electrician for replacement of the obsolete outlet. 

Power Cord Protection

 — Protect the power cord from being walked on or pinched particularly at 

plugs, convenience receptacles and the point where they exit from the amplifier. 

Water

— Do not use the amplifier near water. 

Cleaning

 — Unplug the amplifier from the AC outlet before cleaning.  Use only a dry cloth to clean. 

Object and Liquid Entry 

— Never insert objects of any kind through the openings of these 

amplifiers, as they may touch dangerous voltage points or short-out parts that could result in a fire 
or electric shock.  Care should be taken so that objects do not fall and liquids are not spilled into 
the amplifier through openings in the enclosure. 

Servicing 

— Do not attempt to service these amplifiers yourself, as opening or removing the 

bottom cover WILL expose you to dangerous high voltages.  Refer all servicing to Bob Carver LLC. 

Damage Requiring Service 

— These Amplifiers should be serviced by Bob Carver LLC when: 

 

A power supply connection or a plug has been damaged or 

 

If liquid has been spilled into the amplifier or objects have fallen into the amplifier or 

 

The amplifier has been exposed to water or moisture or 

 

The amplifier does not appear to operate normally or exhibits a marked change in 
performance or 

 

The amplifier has been dropped or the enclosure damaged. 

Содержание CHERRY 180

Страница 1: ...mptuous and enveloping sound stage a great front to back depth of field and very tight pin point imaging within that larger acoustic A special current feedback circuit allows the amplifier to listen t...

Страница 2: ...e The output tubes are arranged in push pull parallel three up three down for a total of six in all The KT88 screen grids are operated at approximately 360 volts provided by a separate power supply fo...

Страница 3: ...control should be left in the maximum fully clockwise position If you have a noisy preamp turning it halfway down and centering it at the 12 00 o clock position will reduce the preamp noise by half or...

Страница 4: ...in power line voltage SPEAKER CONNECTIONS From the rear view the black binding post is common and moving to the right the next red post is two ohms then four ohms and the far right post is for eight...

Страница 5: ...mp sounds good all is well Often an output tube has a spec of dust like impurity which comes into contact with an internal element shorts the element and gets itself vaporized into gaseous oblivion Th...

Страница 6: ...above but write down the current on each tube one at a time You will end up with six numbers The goal is to select two groups of three whose sum from any three tubes is as close as you can get to a si...

Страница 7: ...0 watts Hum 100 dB Frequency Response 2 Hz to 85 kHz 3dB Full Power Bandwidth 24 Hz to 28 kHz Without filters Feedback Control Switch 20dB for Classic Amplifier Sound 11 dB for Contemporary Amplifier...