:MUX
0-15
Decimal representation of a
6 bit binary number
(example: 15 = 1111)
:POLarity
NORMal /
COMPlement /
INVerted
Normal is active HIGH,
Inverted and Complement
are active LOW.
:OUTPut
Command to change the
channels‟ output
parameters.
:AMPLitude
3.3 - 5 [V]
Allows the user to select
adjustable TTL/CMOS
output voltages.
:CMODe
NORMal / SINGle
/
BURSt / DCYCle
Allows the user to select the
pattern of outputs to use on
the channel level.
:BCOunter
1 to 1,000,000
When the channel is in
Burst mode will allow user
to select the number of
pulses to output with each
input clock pulse.
*Note: The commas should
be omitted.
:PCOunter
1 to 1,000,000
When the channel is in duty
cycle mode will allow the
user to select the number of
pulses to create with each
input clock pulse.
*Note: The commas should
be omitted.
:OCOunter
1 to 1,000,000
When the channel is in duty
cycle mode will allow the
user to select the number of
pulses to suppress with
each input clock pulse.
*Note: The commas should
be omitted.
:WCOunter
0 to 1,000,000
Allows user to select how
many clock cycles to wait
until the channel should
start creating an output
pulse.
*Note: commas should be
omitted.
:CGATe
DIS / LOW / HIGH
Channel Gate Subsystem.
Contains commands to
control using the gate input
to control the output
channel.
Command
Keyword 1
Keyword 2 Keyword 3
Parameter
Range
Notes
:SYSTem
Command to change the
units‟ system settings.
:STATe
?
Query Only Command
:BEEPer
Command to change the
units‟ beeper settings.
:STATe
0/1 or OFF/ON
Command to turn on or off
the systems' beeper.