4.  INSTALATION 

 
 
 
 
 
 

After choosing a suitable location (see previous section) install the unit as follows:- 
The unit is suitable for connection to a 230 V ac 50Hz electricity supply. It is suggested that 3-core round flexible cable 
of 1.5 sq. mm gauge is used. An internal switch should be installed to switch the power to the unit ON & OFF. This 
allows the sensor to be easily switched off when not required or for maintenance purposes. 

This product is designed to be mounted on walls 
or under eaves, see diagram E. The sensor can 
be  rotated  through  180  degrees  to  direct 
detection where required, consider your location 
carefully before installation. 
Unscrew  the  wiring  box  fixing  screw  shown  on 
diagram  F.  This  screw  is  captive,  do  not  fully 
remove. 
Detach the wiring box from the Sensor body. 
Using  the  wall  plate  as  a  template,  mark  the 
position of the fitting holes. 
Drill the holes. Insert the wall plugs into the holes. 
PIERCE  &  PASS  THE  CABLE(S)  THROUGH 
THE GROMMET(S) BEFORE PROCEEDING. 
It  is  recommended  that  the  grommet  is  pierced 
with a screwdriver to ensure a better seal. 
Attach  the  mounting  plate  to  the  wall  using 
screws  provided.  Do  not  overtighten  the 
mounting screws as this could damage the unit. 
If  using  a  power  screwdriver,  use  the  lowest 
torque setting. 
This unit features an installation aid. Simply hang 
the Sensor onto the wall plate by use of the clip 
arrangement on  the wall plate. See diagram H. 
This  allows  you  to  use  your  hands  to  hold  the 
screwdriver, and install the incoming cables with 
ease. 
Connect  the  incoming  and  outgoing  cables  as 
follows. 

 

CONNECTION 

Connect  the  mains  supply  cable  to  the 
terminal  block  on  the  unit  as  follows  (see 
connection diagram):  
NEUTRAL (Blue) 

EARTH (Green/Yellow) 

LIVE (Brown) 

Connect the cable from the heating load to the 
terminal  block  on  the  unit  as  follows  (see 
connection diagram):  
NEUTRAL (Blue) 

EARTH (Green/Yellow) 

LIVE (Brown) 

L1 

Ensure that connections are secure. 
Ensure the terminal block is attached to its mounting posts in the sensor body. 
Un-hook the sensor unit from the wall plate and re-attach to the wall plate box as follows:- 

1)  Ensure no wires are trapped. 
2)  Align  the  sensor  centrally  over  the  wiring  box  and  attach  the  top  edge  of  the  sensor  to  the  wall  plate.  See 

diagram I. 

3)  There will be an audible click indicating that the top clips are located into the wall plate. Slowly rotate the sensor 

body downwards and ensure no wires are trapped, the lower edge of the unit will locate into the wall plate. Fully 
tighten the fixing screw. See diagram F.  

I M P O R T A N T  

Switch off the electricity at the fuse box by removing the relevant fuse or 

switching off the circuit breaker before proceeding with the installation 

 