3 . M O U N T I N G I N S T A L L A T I O N
❑
IMPORTANT!
Ensure that the mounting surface / ceiling supports are capable
of taking the additional weight of the heater.
❑
IMPORTANT!
Before cutting out the hole to take the heater ensure there is
200mm clearance behind and that there are no cables or pipes in the way.
The heater is intended for installation in ceilings, walls or bulkheads. When wall
mounted the heater MUST be positioned horizontally. For optimum results do not fit
in ceilings lower than 1.8m or higher than 3m. As air is only introduced through the
front of the unit the heater may be sited anywhere. The air intake and discharge
areas must be kept completely clear for a minimum of 1.5m from the front of the
heater. In an area using multiple units, heaters should be spread to provide an even
heat distribution.
Cut a rectangular hole 315mm long x 150mm wide (See drawing to the right).
The heater should be held in position using suitable fixtures using the pre-punched
slots / holes in the face of the unit.
4 . EL E C T R I C A L C O N N E C T I O N S
230V SINGLE PHASE
– Power Connection
Please make sure you have read the Safety instructions and that you are a suitably qualified electrician before continuing.
Drawings show connections inside the black terminal box on the outside of the heater.
Do NOT use power tools to undo or do up terminal screws in the Power Supply Box.
Please Note: - Specified cable sizes are for typical installations, correction factors may need to be used when determining actual cable sizes.
Standard Connection
Use 1.5mm² 3 Core Mains Cable (see note above).
Connect Brown wire
– Terminal 1 or L.
Connect Blue wire
– Terminal 5 or N.
Connect Green / Yellow wire
– Terminal E or
PLEASE CHECK ALL CONNECTIONS BEFORE TURNING ON AS INCORRECT WIRING IS NOT COVERED
BY THE GUARANTEE
Once the mains cable has been connected the heater will
not work until a suitable controller is attached
to the
heater using a CAT5 network cable. We recommend you use our cables as they have been tested for
compatibility between all the controllers and the various different heater models. Instructions on connecting
controllers is found within the controller packaging.
5 . M A I N T E N A N C E
Note:
Before examining or carrying out any maintenance ensure the heater has cooled down and is disconnected from the mains supply.
The heaters are intended to operate for many years, problem free. All moving parts are factory lubricated and therefore should require no service.
Maintenance is limited to keeping both the inlet and outlet areas free from any accumulation of dust or any other foreign materials. This is especially
important immediately before the heating season. Any dust build up can be loosened using a brush and a vacuum cleaner applied to the airways to
ensure completed removal of any dust. When the heater is first turned on after cleaning an unusual odour may be noted this is due to the dust
particles which inevitably will be disturbed and will be burnt off from the heating element.
If in any doubt always consult a qualified electrician for advice.
6 . A U T O C U T O U T
This heater is fitted with a semi-automatic safety device to prevent overheating. The device will isolate the heating element while the fan continues
to operate. Should this occur, disconnect the heater from the mains supply for a minimum of 5 minutes, check and remove any foreign materials
around the airways. If the heater fails to operate or the safety cut out operates again, turn off the heater and contact a qualified electrician.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without
prior notice.
IMPORTANT:
No liability is accepted for incorrect use of this product.
WARRANTY:
Your BN Thermic product is guaranteed for one year from date of purchase. We will
repair or replace at our discretion any part found to be defective. We cannot assume any consequential
liability. This guarantee in no way prejudices your rights under common law and is offered as an
addition to consumer liability rights.
REGISTER:
Activate your warranty by registering online at www.bnthermic.co.uk and retain this
installation data for future reference.
XR-20INS-v01-1
This product conforms to EU Directive 2002/96/EC.
This appliance bears the symbol of the crossed waste bin. This indicates that, at the end of its useful life, it must not be disposed of as
domestic waste, but must be taken to a collection centre for waste electrical and electronic equipment. It is the user's responsibility to
dispose of this appliance through the appropriate channels. Failure to do so may incur penalties established by laws governing waste
disposal.
BN Thermic Ltd,
34 Stephenson Way,
Crawley, RH10 1TN
Tel: +44 (0) 1293 547361
Email: [email protected]