background image

 

 

3 .   M O U N T I N G   I N S T A L L A T I O N  

 

 

IMPORTANT!

 Ensure that the mounting surface / ceiling supports are capable 

of taking the additional weight of the heater.  

 

IMPORTANT!

  Before  cutting  out  the  hole  to  take  the  heater  ensure  there  is 

200mm clearance behind and that there are no cables or pipes in the way.

 

The  heater  is  intended  for  installation  in  ceilings,  walls  or  bulkheads.  When  wall 
mounted the heater MUST be positioned horizontally. For optimum results do not fit 
in ceilings lower than 1.8m or higher than 3m. As air is only introduced through the 
front  of  the  unit  the  heater  may  be  sited  anywhere.  The  air  intake  and  discharge 
areas  must  be  kept  completely  clear  for  a  minimum  of  1.5m  from  the  front  of  the 
heater. In an area using multiple units, heaters should be spread to provide an even 
heat distribution.  

Cut a rectangular hole 315mm long x 150mm wide (See drawing to the right).  

The  heater should be  held in  position  using suitable  fixtures  using  the  pre-punched 
slots / holes in the face of the unit. 

4 .   EL E C T R I C A L   C O N N E C T I O N S  

230V SINGLE PHASE 

– Power Connection 

Please make sure you have read the Safety instructions and that you are a suitably qualified electrician before continuing. 
Drawings show connections inside the black terminal box on the outside of the heater. 

Do NOT use power tools to undo or do up terminal screws in the Power Supply Box. 

Please Note: - Specified cable sizes are for typical installations, correction factors may need to be used when determining actual cable sizes. 

 

 
Standard Connection 
 
Use 1.5mm² 3 Core Mains Cable (see note above). 
Connect Brown wire 

– Terminal 1 or L. 

Connect Blue wire 

– Terminal 5 or N. 

Connect Green / Yellow wire 

– Terminal E or 

 

PLEASE CHECK ALL CONNECTIONS BEFORE TURNING ON AS INCORRECT WIRING IS NOT COVERED 
BY THE GUARANTEE 
 
 

Once the mains cable has been connected the heater will 

not work until a suitable controller is attached

 to the 

heater  using  a  CAT5  network  cable.  We  recommend  you  use  our  cables  as  they  have  been  tested  for 
compatibility  between  all  the  controllers  and  the  various  different  heater  models.  Instructions  on  connecting 
controllers is found within the controller packaging.  

 

 

 

 

 

 

5 .   M A I N T E N A N C E

 

Note:

 Before examining or carrying out any maintenance ensure the heater has cooled down and is disconnected from the mains supply. 

The heaters are intended to operate for many years, problem free. All moving parts are factory lubricated and therefore should require no service. 
Maintenance is limited to keeping both the inlet and outlet areas free from any accumulation of dust or any other foreign materials. This is especially 
important immediately before the heating season. Any dust build up can be loosened using a brush and a vacuum cleaner applied to the airways to 
ensure  completed  removal  of  any  dust.  When  the  heater  is  first  turned  on  after  cleaning  an  unusual  odour  may  be  noted  this  is  due  to  the  dust 
particles which inevitably will be disturbed and will be burnt off from the heating element. 

If in any doubt always consult a qualified electrician for advice. 

 

6 .   A U T O   C U T   O U T

 

 

This heater is fitted with a semi-automatic safety device to prevent overheating.  The device will isolate the heating element while the fan continues 
to operate. Should this occur,  disconnect the heater from the mains supply for a minimum of 5 minutes,  check and remove any foreign materials 
around the airways. If the heater fails to operate or the safety cut out operates again, turn off the heater and contact a qualified electrician. 

 

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without 
prior notice. 

 

IMPORTANT: 

No liability is accepted for incorrect use of this product.

 

WARRANTY: 

Your  BN  Thermic  product  is  guaranteed  for  one  year  from  date  of  purchase.  We  will 

repair or replace at our discretion any part found to be defective. We cannot assume any consequential 
liability.  This  guarantee  in  no  way  prejudices  your  rights  under  common  law  and  is  offered  as  an 
addition to consumer liability rights. 

REGISTER:

 Activate your warranty by registering online at www.bnthermic.co.uk and retain this 

installation data for future reference. 

 

 

 

 

 

 

 

 

 

 

XR-20INS-v01-1 

This product conforms to EU Directive 2002/96/EC. 
This appliance bears the symbol of the crossed waste bin. This indicates that, at the end of its useful life, it must not be disposed of as 
domestic  waste,  but  must  be  taken  to  a  collection  centre  for  waste  electrical  and  electronic  equipment.  It  is  the  user's  responsibility  to 
dispose  of  this  appliance  through  the  appropriate  channels.  Failure  to  do  so  may  incur  penalties  established  by  laws  governing  waste 
disposal.

 

BN Thermic Ltd,  

34 Stephenson Way, 

 Crawley, RH10 1TN 

Tel: +44 (0) 1293 547361 

Email: [email protected] 

Web: www.bnthermic.co.uk 

 