3 .   M O U N T I N G   I N S T A L L A T I O N  

 

3.1 

CEILING MOUNTING 

The heater is intended for installation in a suspended ceiling mounted within or on the 'tee' bar supports. For optimum results do not fit in ceilings 
higher than 4m. As air is only introduced through the front of the unit the heater may be sighted anywhere. The air intake and discharge areas must 
be kept completely clear for a minimum of 1.5m from the front of the heater. In an area using multiple units, heaters should  be spread to provide an 
even heat distribution. 

 

IMPORTANT! 

A  minimum  clearance  of  205mm  is  needed  between  the  bottom  of  the  false  ceiling  and  the  original  roof/ceiling  to  allow 

installation of the heater. 

 

IMPORTANT! 

DO NOT use plastic type diffusers as these may be damaged by the heat. 

 

IMPORTANT!

 Ensure that  the mounting  surface  /  ceiling supports are  capable of  taking  the  additional  weight  of the  heater there  are 4  eye 

hooks supplied with the heater that should be used if additional support of the heater is required. 
When using the diffuser the four Z brackets provided should be attached to the side of the heater to enable the heater to be supported by the 'tee' 
bar and immediately above the diffuser. 

 

4 .   EL E C T R I C A L   C O N N E C T I O N S  

 

230V SINGLE PHASE 

– Power Connection 

 

Please make sure you have read the Safety instructions and that you are a suitably qualified electrician before 
continuing. 
Drawings show connections inside the black terminal box on the outside of the heater. 

Do NOT use power tools to undo or do up terminal screws in the Power Supply Box. 

Please Note: - Specified cable sizes are for typical installations, correction factors may need to be used when 
determining actual cable sizes. 

 

 
Standard Connection 

 
 
 

Use 4mm² 3 Core Mains Cable (see note above). 
Connect Brown wire 

– Terminal 1 or L. 

Connect Blue wire 

– Terminal 5 or N. 

Connect Green / Yellow wire 

– Terminal E or 

 
 
 

PLEASE CHECK ALL CONNECTIONS BEFORE TURNING ON AS INCORRECT WIRING IS NOT COVERED 
BY THE GUARANTEE 

 
 

Once the mains cable has been connected the heater will 

not work until a suitable controller is attached

 to the 

heater  using  a  CAT5  network  cable.  We  recommend  you  use  our  cables  as  they  have  been  tested  for 
compatibility  between  all  the  controllers  and  the  various  different  heater  models.  Instructions  on  connecting 
controllers is found within the controller packaging.  

 

5. M A I N T E N A N C E

 

Note:

 Before examining or carrying out any maintenance ensure the heater has cooled down and is disconnected from the mains supply. 

The heaters are intended to operate for many years, problem free. All moving parts are factory lubricated and therefore should require no service. 
Maintenance is limited to keeping both the inlet and outlet areas free from any accumulation of dust or any other foreign materials. This is especially 
important immediately before the heating season. Any dust build up can be loosened using a brush and a vacuum cleaner applied to the airways to 
ensure  completed  removal  of  any  dust.  When  the  heater  is  first  turned  on  after  cleaning  an  unusual  odour  may  be  noted  this  is  due  to  the  dust 
particles which inevitably will be disturbed and will be burnt off from the heating element. 

If in any doubt always consult a qualified electrician for advice. 

 

6. A U T O   C U T   O U T   /   F U S E   R E PL A C E M E N T

 

Each heater element is fitted with a semi-automatic safety device to prevent overheating.  The device will isolate the heating element while the fan 
continues to operate. Should this occur,  disconnect the heater from the mains supply for a minimum of 5 minutes,  check and remove any foreign 
materials  around  the  airways.  If  the  element  fails  to  operate  or  the  safety  cut  out  operates  again,  turn  off  the  heater  and  contact  a  qualified 
electrician. This unit is fused and the fuse holder is located on the inside of the heater near the internal wire connection boxes. Should the fuse fail, 
ensure the heater has cooled down  and is disconnected from the mains supply before replacing with another 12.5A fuse. If this replacement fuse 
fails seek professional help. 

 
 

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior 
notice. 

 
 

IMPORTANT: 

No liability is accepted for incorrect use of this product.

 

WARRANTY: 

Your BN Thermic product is guaranteed for one year from date of purchase. We will 

repair  or  replace  at  our  discretion  any  part  found  to  be  defective.  We  cannot  assume  any 
consequential  liability.  This  guarantee  in  no  way  prejudices  your  rights  under  common  law  and  is 
offered as an addition to consumer liability rights. 

REGISTER:

 Activate your warranty by registering online at www.bnthermic.co.uk and retain this 

installation data for future reference. 

 

 

 

 

 

 

 

 

 

 

XC-60INS-v01-2 

This product conforms to EU Directive 2002/96/EC. 
This appliance bears the symbol of the crossed waste bin. This indicates that, at the end of its useful life, it must not be disposed of as 
domestic waste, but must be taken to a collection centre for waste electrical and electronic equipment. It is the user's responsibility to 
dispose of this appliance through the  appropriate channels. Failure to do so may incur penalties established by laws governing waste 
disposal.

 

BN Thermic Ltd,  

34 Stephenson Way, 

 Crawley, RH10 1TN 

Tel: +44 (0) 1293 547361 

Email: [email protected] 

Web: www.bnthermic.co.uk 

 

Отзывы: