background image

 

 
 
 
 

 

 

Thank you for purchasing a BN Thermic product. Manufactured to a high standard this product will, if used according to these instructions and properly 
maintained, give you years of trouble free performance. 

 
 
 
 
 

 
 
 
 
 
 
 

 
 

1. S A F ET Y  I N ST R U C T I O N S  

 

1 . 1               ELECTRICAL SAFETY

 

 

WARNING!

 It is the responsibility of the owner and the operator to read, understand and comply with the following:  

 

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, socke ts and any 
other  connectors  for  wear  or  damage.  You  must  ensure  that  the  risk  of  electric  shock  is  minimised  by  the  installation  of  appropriate 
safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. If in any doubt consult a qualified 
electrician. You must also read and understand the following instructions concerning electrical safety.

 

1.1.1  The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those  appliances and the 

safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician. 

1.1.2  Ensure that the insulation of all the cables on the appliance is safe before connecting it to the power supply.  
1.1.3   Ensure that the cables are always protected against short circuit and overload. 
1.1.4  Regularly inspect the power supply cables and plugs etc. for wear or damage and check all connections to ensure that none are loose. 
1.1.5   Important: Ensure that the voltage marked on the appliance matches the power supply to be used and that a correctly rated fuse is fitted. 
1.1.6  Installation should always be carried out by a qualified electrician in accordance with current electrical regulation, protected by a suitably rated 

isolator and fuse or mcb. 

1.1.7  DO NOT use worn or damaged cables or connectors. Immediately have any faulty item repaired or replaced by a qualified electrician. 
1.1.8  If the supply cord is damaged, it must be replaced by the manufacturer or 

it’s service agent. 

1.19 

Do not use in hazardous areas. 

1.2 GENERAL SAFETY INSTRUCTIONS 

 

Remove all packaging and store it away from children, check the package and heater for visible damage or tampering. 

 

Familiarise yourself with the applications and limi tations of the heater. 

 

Ensure  the  heater  is  in  good  order  and  condition  both  physically  and  electrically  before  use.  If  in  any  doubt  do  not  use  the  unit  and 
contact your supplier.

 

 

Disconnect from mains and allow to cool before attempting any cleaning.

 

X

 

DO NOT

 use in hazardous areas. 

X

 

DO NOT 

use if ambient temperatures exceed 30°C.  

X

 

DO NOT

 cover the heater or restrict free circulation of air around it. 

X

 

DO NOT

 locate the heater below the power outlet. 

X

 

DO NOT

 install this heater against combustible low-density fibre board surfaces. 

X

 

DO  NOT

  disassemble  the  heater  for  any  reason.  This  heater  must  be  checked  by 

qualified personnel only.

 

X

 

DO NOT

 use this heater to perform a task for which it has not been designed. 

 

WARNING!

 

This heater is not equipped with a device to control the room temperature. 

Do not use this heater in a small room if it is occupied by people not capable of leaving 
the room on their own, unless constant supervision is provided. 

 

 

WARNING! 

Ensure  there  is  no  possibility  of  inflammable  materials  coming  into 

contact with the heater.

 

 
 
 
 

2 .   IN T R O D U C T I O N  &  S P E C I F IC A T I O N

 

 

RP3 Ceiling Panels are designed to provide primary, localised or perimeter heating. The heaters 
should be ceiling mounted ideally between 2.4m and 3.5m from floor level. RP3 Ceiling Panels are 
a  more  economic  means  of  heating  commercial  premises  than  conventional  heating  systems 
because the gentle radiant effect felt from them 

means that the ‘experienced temperature’ can be 

up to 4°C warmer than the actual air temperature. This means that the thermostat can be set up 
to 4°C lower saving power and electricity costs. A suitable air sensing thermostat and timer should 
be used.  

Model 

RP3-03 

RP3-06 

Power 

300W 

600W 

Input supply 

230V 50Hz 1.3A 

230V 50Hz 2.6A 

Dimensions (W x H x D) 

592 x 592 x 30mm 

1192 x 592 x 30mm 

Weight 

5.9Kg 

11.3Kg 

Minimum Mounting Height 

1.8M 

1.8M 

Recommended Mounting Height 

2.4 

– 3.5M 

2.4 

– 3.5M 

IP rating 

IP44 

IP44 

INSTRUCTIONS FOR:- 

RADIANT CEILING PANELS 

RP3 Series

 

IMPORTAN

T:  PLEASE  READ  THESE  INSTRUCTIONS,  NOTE  THE  SAFE  OPERATIONAL  REQUIREMENTS,  WARNINGS,  AND 

CAUTIONS. USE THIS PRODUCT CORRECTLY, AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO 
DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. 

 

REGISTER

: PLEASE REGISTER THIS PRODUCT ONLINE TO ACTIVATE YOUR GUARANTEE AT 

 www.

bnthermic

.co.uk 

Отзывы: