BN Thermic HCA2 Series Скачать руководство пользователя страница 6

 

 

 

Содержание HCA2 Series

Страница 1: ...ly to be used DO NOT use worn or damaged cables plugs or connectors Immediately have any faulty item repaired or replaced by a qualified electrician The unit should be protected by a suitably rated isolator and MCB This air curtain is IP20 rated and is suitable for indoor or under cover use only This air curtain must be hard wired in position 1 2 GENERAL SAFETY INSTRUCTIONS Remove all packaging an...

Страница 2: ...ling mounted at a recommended height of 2 5 4m above floor level making sure you leave a minimum of 110mm from the ceiling to the top of the air curtain IMPORTANT DO NOT mount air curtain directly below the power isolator IMPORTANT Ensure that the mounting surface ceiling supports are capable of taking the weight of the air curtain IMPORTANT Always mount the air curtain horizontally Mounting at an...

Страница 3: ...ed to take the weight of the air curtain You may find it easier to remove the front cover to expose the electrics before mounting the air curtain onto its bracket If so see section 5 Fold the two tabs outwards as shown in diagram to the right Using 2 people lift the air curtain onto the wall bracket and secure in place by using the 2 x M4 fixing bolts provided see drawing below Model Dimension A H...

Страница 4: ...ess See drawings below showing the spacing and positioning of the drop rods You may find it easier to remove the front cover to expose the electrics before mounting the air curtain onto its drop rods If so see section 5 Make sure you use a minimum of two persons to lift the air curtain into position Use M6 nuts to lock each drop rod in position ensuring they will not twist once installed DROP ROD ...

Страница 5: ...ator BUT this isolator should NOT be used as a way of turning on and off the air curtain except in an emergency due to the fan overrun being disabled causing the safety cut out to trip which will need manual resetting each time Standard every day on and off switching of the air curtain must be performed using the SystemX wall control box Two Ø25mm holes are provided on both sides of the air curtai...

Страница 6: ...6 ...

Страница 7: ...ontinue running creating a curtain of air when the heating elements turn off See controller instructions for more information CX6 Programmable controller Thermostat range 5 to 30 C 7 day or 5 2 days programming Up to 6 programable events per day Settings on off high heat low heat fan only Mounting Surface Dimensions 120 x 80 x 40mm Maximum No of air curtains controlled 12 Notes The internal defaul...

Страница 8: ...turbed and be burnt off from the heating element If in any doubt always consult a qualified electrician for advice 10 OVER TEMPERATURE PROTECTION FUSE REPLACMENT Two thermal protection switches are fitted to the air curtain One thermal switch provides the fan over run The fan will either continue to run after the unit is switched off on the wall control switch until the air temperature in the casi...

Отзывы: