3. MOUNTING INSTALLATION 

 

3.

1     WALL MOUNTING (see Fig.1) 

 

IMPORTANT!

 The following points should be noted: 

The heater should always have a minimum 

clearance of 450mm from a ceiling and be at least 1.2M from any object (see table on front 
page). 

 

IMPORTANT!

 Ensure that the mounting surface is capable of supporting the weight of the heater. 

 

IMPORTANT!

 The heater should be mounted at 30º to 45º from the vertical. 

 

IMPORTANT! 

The mounting bracket must be sufficiently earthed. 

3.1.1 Before drilling, ensure that there are no wires or water pipes in the area where the heater is to be 

placed. 

3.1.2 Use the bracket as a template. Fix the metal bracket to the wall by means of the three holes and 

appropriate fixings (not supplied). 

3.1.3  Refit the heater onto the bracket with the bolt provided. 
3.1.4  Adjust the angle of heater to direct heat where required, between 30° and 45° (see Fig.1). 

 

3.2     CEILING MOUNTING 

3.2.1  An optional pack containing 4 hooks and nuts is available from your supplier to enable the heater 

to be ceiling mounted on suitable chains. 

3.2.2  Insert these 4 hooks into the M6 threaded holes in the back corners of the heater and lock in place 

with the supplied nuts. 

3.2.3    Heaters  can  be  hung  horizontal  to  the  floor  or  at  an  angle.  If  hung  at  an  angle  this  should  be 

ideally be 30º to 45º making sure the ceramic element remains in a horizontal position to the floor. 

 

4. ELECTRICAL CONNECTIONS 

4.1 

 230V INSTALATION 

4.2 

Please make sure you have read the Safety instructions and you are a suitably qualified electrician 
before continuing. 

4.3 

This heater is factory fitted with high temperature silicon rubber flexible cable conforming to BS 6500 having a temperature rating of 180°C.  

4.4 

Heaters must be earthed. 

4.5 

Connection to a Switched Fused Spur / Isolator.

 

a)  Connect the GREEN/YELLOW earth wire to the earth connection.

 

b)  Connect the BROWN live wire to the live 

connection. 

c)  Connect  the  BLUE  neutral  wire  to  the 

neutral connection. 

d)  After wiring, check that there are no bare 

wires,  that  all  wires  have  been  correctly 
connected, that the cable outer insulation 
extends  beyond  the  cable  restraints  and 
that the restraint is tight.

 

 

 

5. COMMISSIONING 

 

Note: 

The Heater runs hot so please wait till it has cooled down before moving / adjusting. 

WARNING! Ensure you read, understand and apply the safety instructions in Section 1 before using the heater.  

5.1    Perform insulation and earth continuity tests.

 

5.2  Switch on the heater and confirm that the ceramic elements are working. 
5.3  Ensure  each  heater  aims  its  warmth  into  the  target  area  by  adjusting  the  heater  angle(s)  as  required,  and  then  tighten  the  bracket  bolts 

keeping the heater firmly in place while doing so. 

5.4  Make sure you maintain an angle between 30º & 45º in the vertical plane.  
5.5  The user / customer should be made aware of all aspects of the operation and safety advice. Keep the instructions safely for future reference. 
5.6 

In unoccupied premises it is recommended that the heating system is switched of and isolated from the electrical supply. 

 

6. MAINTENANCE 

 

Note:

 Before examining or carrying out any maintenance ensure the heater has cooled down and is disconnected from the mains supply.  

6.1

  

Ceramic  Heaters  contain  no  moving  parts  and  therefore  very  little maintenance  is  required  other  than  to  ensure  that  there  is  no  excessive 
build-up  of  dust  /  dirt  on  the  reflectors  or  ceramic  elements  especially  after  a  long  period  of  non-use  as  this  can  cause  overheating  and 
premature ceramic failure. Depending on installation conditions the heater should be regularly inspected, but at least once per year. 

 

Spare ceramic elements and reflectors are available contact your supplier for details. 
 

 

NOTE:  It  is  our  policy  to  continually  improve  products  and  as  such  we  reserve  the  right  to  alter  data, 
specifications and component parts without prior notice. 
IMPORTANT: 

No liability is accepted for incorrect use of this product.

 

WARRANTY: 

Your BN Thermic product is guaranteed for one year from date of purchase. We will repair or 

replace at our discretion any part found to be defective. We cannot assume any consequential liability. This 
guarantee  in  no  way  prejudices  your  rights  under  common  law  and  is  offered  as  an  addition  to  consumer 
liability rights. 

REGISTER:

  Activate  your  warranty  by  registering  online  at  www.bnthermic.co.uk  and  retain  this  installation 

data for future reference. 

 

 

 

 

 

 

 

 

 

                CH2-30LINS-v01 

Fig.1 

Отзывы: