9
Electric�coolant�pump�for�exhaust�turbocharger
10
Exhaust�turbocharger
The�electric�coolant�pump�for�the�turbochargers�is�a�20 W�pump�which�communicates�with�the
DME�via�a�LIN�bus.�The�conventional�coolant�pump�is�driven�via�the�drive�belt�and�cannot�be�used
for�cooling�the�exhaust�turbocharger�after�the�engine�has�shut�down.�This�is�why�there�is�an�electric
coolant�pump�for�this�separate�cooling�circuit.�But�also�during�engine�operation�the�electric�coolant
pump�is�switched�on�taking�into�account�the�following�factors:
•
Coolant�temperature�at�the�engine�outlet
•
Engine�oil�temperature
•
Injected�fuel�quantity
Using�these�values�the�heat�input�into�the�engine�is�calculated.�The�run-on�period�of�the�electric
coolant�pump�can�last�up�to�30 min.�To�improve�the�cooling�effect,�the�electric�fan�also�cuts�in�and�may
run�on�for�up�to�11 min.