32
Figure 26:
AGS Energy Center Settings
Energy Settings
Press
Energy Settings
to set the parameters to control AGS usage.
USE AGS TO SUPPORT
Choose if AGS is to support battery levels, climate or both.
BATTERY LEVELS
Nominate the battery voltage (min) level which automatically starts battery
charging from the generator. Battery charging stops when the target voltage is
reached.
AGS monitors both system voltage and coach battery voltage and uses the greater
of the two voltages to determine whether to turn the generator on or off.
RUN TIME LIMITS
Set the
minimum time
that the generator will continue to run after the goal
battery voltage and/or temperature is achieved. The
maximum time
is the total
run time that the generator will operate to achieve the target battery voltage
and/or temperature. If targets are not achieved and the generator run time
exceeds the maximum run time limit set in the Energy Settings, the generator will
automatically turn off.
QUIET TIME
Quiet Time allows you to choose the hours when the generator will always be
turned off, even if AGS has been enabled.
WARNING
If using Quiet Time, please ensure that time is correct on the Controller. For more help
on setting the time, refer to