8
u
REMOTE SWITCH TERMINAL BLOCK (RSW)
To connect the caravan’s remote switch. This switch is used to enter Storage
Mode and power off all outputs (load terminal block and CAN bus) on the
BatteryPlus35
.
If the switch is activated and the
BatteryPlus35
is connected to a charging source,
the
BatteryPlus35
will enter ECO mode. Terminal 1 on the load terminal block and
CAN bus will still receive power.
Battery charging is not affected by use of the RSW.
As the caravan loads are no longer powered, activating the RSW to enter Storage
Mode is a convenient way to save remaining power of your battery if you are on
the road and have limited ability to charge the battery. When charging, Storage
Mode ensures that all available charging current is dedicated to charging your
battery.
i
LOAD OUTPUT STATUS INDICATOR
LED bank indicating the operational status, one for each of the load outputs on the
BatteryPlus35
Load Terminal Block.
The LED bank is located inside of the
BatteryPlus35
unit, and to view the LED, one
must be directly above the
BatteryPlus35
.
LED COLOUR
LOAD OPERATIONAL STATUS
GREEN
Load operating normally
RED
Fault with load
OFF
Load is off
Table 3:
Load Output Operational Status Indications
o
SYSTEM STATUS INDICATOR
Indicates the operational status of the
BatteryPlus35
.
a
CAN BUS COMMUNICATION CONNECTOR
To connect to and power BMPRO accessories (
BC300 + CommLink
External Shunt
or
OdysseyLink
) or monitors (
RVView
or
Trek
).
sd
NOT IN USE