5.5 Checking accuracies of plumb beams (up and down)
Mount the device on the multi-functional adapter and on a tripod
(1) Set up the device on a tripod 1m above ground in a room of 2,5m height
(picture 6).
Turn on the plumb line (button 1, press 3x)
(2) Mark the laser point on the ground with A, the point on the ceiling with B
(3) Turn the device on the tripod by 180°, move tripod until plumb down points directly on
point A again. Now name the new point position at ceiling B1
(4) Now name the new point position at ceiling B1
(5) Measure the distance between point B und B1
If the gap is less them 1 mm, the device is conform and respects the tolerances
1,5 m
1 m
A
A