bmcm USB-OI16 Скачать руководство пользователя страница 8

USB-OI16 

Seite 8 

5

 

Important Notes for Using the USB-OI16 

 

The USB-OI16 is only suitable for extra-low voltages 

 please observe the relevant regulations! 

 

An electrically isolated power unit (with CE) must be used for power supply. 

 

All accessible pins are electrostatic sensitive devices. Provide for an earthed conductive work place when 
installing. 

 

Only use non-solvent detergents for cleaning. The product is designed to be maintenance-free. 

 

The board must not be used for safety-relevant tasks. With the use of the product, the customer becomes 
manufacturer by law and is therefore fully responsible for the proper installation and use of the product. In the 
case  of  improper  use  and/or  unauthorized  interference,  our  warranty  ceases  and  any  warranty  claim  is 
excluded. 

 

Do not dispose of the product in the domestic waste or at any waste collection places. It has to be either duly 
disposed according to the WEEE directive or can be returned to bmcm at your own expense. 

6

 

Technical Data   

(typical at 20°C, after 5min., +5V supply)

 

 

Digital Inputs 

Number: 

16 digital inputs, galvanically isolated by 16 optocouplers 

Counters: 

2 counters/incremental encoders (32 bit, opt. counter reset) can be connected at the first digital inputs 

Counter frequency: 

max. 250kHz 

Input voltage: 

3..32V DC (>2.5V = high) 

Surge protection: 

max. 60V DC for 10sec. 

Input current // Input resistance: 

max. 0.35mA // app. 100k  

 

Digital Outputs 

Number: 

16 digital outputs, galvanically isolated by 16 optocouplers with 2 high-side drivers 

Switching voltage: 

5V DC (internal supply) or 7..32V DC (external supply) 

Voltage drop (with ext. supply): 

app. 1.5V at the high-side driver 

Switching current (with ext. supply): 

max. 0.25A per output, max. 0.8A in total per 8-bit high-side driver at 25°C 

 

General 

Power supply: 

internal: 5V DC; external: 7..32V DC at 37-pin D-Sub female 

Digital connection: 

37-pin D-Sub female 

USB interface: 

attach to PC at USB connector (type B), USB 2.0 

CE standards: 

EN61000-6-1, EN61000-6-3, EN61010-1; for decl. of conformity (PDF) visi

www.bmcm.de

 

ElektroG // ear registration: 

RoHS and WEEE compliant // WEEE Reg.-No. DE75472248 

Max. perm. potentials (galv. isolation): 

60V DC acc. to VDE, max. 1kV ESD on open lines 

Temperature ranges: 

operating temp. -25..60 C, storage temp. -25..70 C 

Relative humidity: 

0..90% (not condensing) 

Dimensions (L x W x H): 

app. 97mm x 105mm x 30mm 

Delivery: 

device with DIN rail carrier and bracket, USB cable 

Available accessories (optional): 

connecting cables ZUKA37SB, ZUKA37SS, D-Sub plug ZU37ST,  

gender changer ZU37SS, waterproof housings ZU-PBOX-PG 

Warranty: 

2 years from date of purchase at bmcm, claims for damages resulting from improper use excluded 

 

Software 

Software free of charge download: 

LIBAD4 SDK for C/C++ programming on Windows

® 

XP/7/8/10, Mac OS X, Unix (FreeBSD, Linux); trial version 

of the measuring software NextView

®

 to test and operate the hardware 

NextView

®

 (optional): 

professional software (versions: Professional, Lite) for the acquisition and analysis of measurement data on 

Windows

®

 8/10 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manufacturer: BMC Messsysteme GmbH. Subject to change due to technical improvements. Errors and printing errors excepted. Rev. 2.3   

02/11/2020

 

Содержание USB-OI16

Страница 1: ...me measurement function produces precise results especially in the low frequency range Get Connected The digital channels of the application specific hardware sensor machine etc are connected at a 37 pin D Sub female Plug Play The connection to the PC is realized via USB The USB OI16 provides all typical USB features e g Plug Play Hot Plug Up to 127 devices can be connected and installed during op...

Страница 2: ...tage higher than the 5V of the USB interface an external power supply providing 7 32V can be connected 3a Step Measuring with NextView To be able to use your measurement system with NextView you just need to download and install the latest version of NextView on www nextview de download In case you did not buy NextView request a free of charge trial version when first starting NextView Find more i...

Страница 3: ...USB OI16 Seite 3 2 Block Diagram µCont roller USB OUT 1 16 D D 1 7 32V ext 2 9 8 10 B 16 IN 1 16 1 2 3 16 15 A DC DC Treiber Driver 5V i nt Treiber Driver ...

Страница 4: ...icated to the inputs and outputs are turned on when a digital channel is high 3 2 Connection to the PC The standard USB connector type B serves for the connection of the USB OI16 to the PC 5V voltage supply is also provided via the USB interface 3 3 Switching Voltage A 7 32V DC switching voltage for the digital outputs can be connected at the 37 pin D Sub female If there is no external power suppl...

Страница 5: ...sensors or other digital signal sources in the 3 32V range at the connections I1 I16 The following table and figure shows the pin assignment of the digital inputs at the 37 pin D Sub female and the related port assignment Digital IN D Sub37 Port Bit Digital IN D Sub37 Port Bit I1 11 A 0 I9 15 A 8 I2 30 A 1 I10 34 A 9 I3 12 A 2 I11 16 A 10 I4 31 A 3 I12 35 A 11 I5 13 A 4 I13 17 A 12 I6 32 A 5 I14 3...

Страница 6: ...ted the counter can be reset at any time In comparison to a counter the quadrature decoder considers the counting direction by decoding a second phase shifted signal To activate the counting function the respective digital lines of the USB OI16 must be assigned to the counter via software Function Description Max pulse frequ Connection Pins Counter Counting range Counter count 250kHz Signal A 1 0 ...

Страница 7: ... and a lamp to USB OI16 with external supply 4 Compatibility of the USB OI16 to USB PIO with OI16 The USB OI16 incorporates all functions in one device provided by the combination of a USB PIO and OI16 Therefore the USB OI16 can serve as an alternative for this hardware combination All previously used applications are fully compatible ...

Страница 8: ... 16 optocouplers with 2 high side drivers Switching voltage 5V DC internal supply or 7 32V DC external supply Voltage drop with ext supply app 1 5V at the high side driver Switching current with ext supply max 0 25A per output max 0 8A in total per 8 bit high side driver at 25 C General Power supply internal 5V DC external 7 32V DC at 37 pin D Sub female Digital connection 37 pin D Sub female USB ...

Отзывы: