6

 

Important notes for using the USB-AD12f 

 

The device is only suitable for extra-low voltages - please observe the relevant regulations! For reasons relating to 
EMC, it must only be used in closed PC housings. ESD voltages at open lines may cause malfunction. 

 

Only use non-solvent detergents for cleaning. The product is designed to be maintenance-free. 

 

Signal cables are connected at the 37-pin or 15-pin D-Sub female connector – preferably use shielded cables. For 
best possible interference suppression, connect shield at one end only. Close open inputs if necessary. 

 

The device ground and the chassis are electrically connected to the chassis of the PC, which is usually also 
connected to ground. Be sure to avoid ground loops since they will cause measuring errors! 

 

PCs (notebooks) which are not grounded often produce high potentials to earth at the USB socket so that safe 
operation cannot be guaranteed. In this case, connect the measuring system to earth. 

 

The gain is adjusted to even values. Therefore, only 4000 values (for 12 bit) of the full range of the converter are 
used. As a result, the measuring ranges are slightly larger (e.g. 

±

10.24V) than the indicated measuring ranges so 

that overranges can be recognized. The AD converter of the USB-AD12f has a code noise of up to 

±

1 LSB. 

 

The device must not be used for safety-relevant tasks. With the use of the product, the customer becomes 
manufacturer by law and is therefore fully responsible for the proper installation and use of the product. In the case 
of improper use and/or unauthorized interference, our warranty ceases and any warranty claim is excluded. 

 

Do not dispose of the product in the domestic waste or at any waste collection places. It has to be either duly 
disposed according to the WEEE directive or can be returned to bmcm at your own expense. 

7

 

Technical data 

(typical at 20°C, after 5min., +5V supply) 

 

Analog inputs 

Channels // Resolution // Sampling rate: 

16 single-ended // 12 bit // max. 20kHz total sampling rate*

Measuring range // Accuracy // Noise: 

±

10V // 

±

5mV // 

±

1 LSB

Surge protection: 

max. 

±

35V (when turned on), 

±

20V (when turned off), max. 

±

20mA in total of all input channels!

Input resistance // Input capacity: 

1M

Ω

 (with PC turned off: 1k

Ω

) // 5pF

Zero shift // Gain drop: 

±

50ppm/

°

C // 

±

50ppm/

°

C

Frequency accuracy // Frequency drift: 

max. 

±

50ppm // max. 

±

50ppm/

°

C

 * The total sampling rate is the sum of the sampling rates of the individual used channels (e.g. if 4 channels are scanned with 5kHz, the total 

sampling rate adds up to 20kHz). 

 

Analog outputs 

Voltage range // Output current: 

1 voltage output with 

±

5V // 1mA max.

Resolution // Accuracy: 

12 bit // typ. 

±

4 LSB, max. 

±

8 LSB

Zero shift // Gain drop: 

±

50ppm/

°

C // 

±

50ppm/

°

C

 

Digital inputs/outputs 

Channels // Level: 

4 input and 4 output channels // CMOS/TTL compatible (low: 0V..0.7V; high: 3V..5V)

Current pick-up per output pin: 

1mA (with app. 4V level), max. 2.5mA (with app. 3V level)

Surge protection: 

max. 

±

5.5V, protected with 1k

Ω

, max. max. 

±

20mA in total of all channels!

Counter: 

use DIn 1 as counter input: 100kHz, 16 bit, 0..5V input voltage

 

General data 

Power supply: 

+4.5V..+5.5V from USB connection to the PC, max. 100mA

USB interface: 

USB 2.0 compatible (full speed)

Connections analog: 

all channels at a 37-pin D-Sub female at the device front

Connections digital: 

all channels at a 15-pin D-Sub female at the device back

CE standards: 

EN61000-6-1, EN61000-6-3, EN61010-1; for decl. of conformity (PDF) visit 

ElektroG // ear registration: 

RoHS and WEEE compliant // WEEE Reg.-No. DE75472248

Max. permissible potentials: 

60V DC acc. to VDE

, max. 1kV ESD on open lines

Temperature ranges // Relative humidity: 

operating temp. 0..70

°

C, storage temp. –25..+85

°

C // 0-90% (not condensing)

 

Dimensions // Protection type: 

167 x 113 x 30 mm

3

 // IP30

Delivery: 

device in aluminum housing, 1m USB connection cable, "Software Collection" CD, description

Available accessories (optional): 

demo board ZU-DBD, DIN rail set ZU-SCHI, current shunt ZU-CS250R, 

connecting cables ZUKA37SB, ZUKA37SS, 37-pin D-Sub plugs ZU37ST, ZU15ST,

connector boards ZU37BB/CB/CO, waterproof housing ZU-PBOX-PG

Warranty: 

2 years from date of purchase at bmcm, claims for damages resulting from improper use excluded

 

Software 

Software on CD (included): 

ActiveX Controls LIBADX (hardware independent) for programming on Windows

®

 7/XP; 

LIBAD4 SDK for C/C++ programming on Windows

® 

7/XP, Mac OS X, Unix (FreeBSD, Linux); 

trial version of the measuring software NextView

®

4 to test and operate the hardware

NextView

®

4 (optional): 

professional software (versions: Professional, Lite) for the acquisition and analysis of measurement 

data on Windows

®

 7/XP

Manufacturer: BMC Messsysteme GmbH. Subject to change due to technical improvements. Errors and printing errors excepted. Rev. 6.0   

12/19/2012

 

Содержание USB-AD12f

Страница 1: ...ounting pulses Plug Play The connection to the PC is realized via USB The USB AD12f provides all typical USB features e g Plug Play Hot Plug Up to 127 devices can be connected and installed during ope...

Страница 2: ...e shows the pin assignment of the 37 pin D Sub connector Pin USB AD12f Pin USB AD12f 1 AIn 1 11 AIn 11 2 AIn 2 12 AIn 12 3 AIn 3 13 AIn 13 4 AIn 4 14 AIn 14 5 AIn 5 15 AIn 15 6 AIn 6 16 AIn 16 7 AIn 7...

Страница 3: ...he digital ground DGND is connected with the PC ground 4 Interfacing examples for the digital lines of the USB AD12f The following basic connection examples demonstrate the use of the digital inputs a...

Страница 4: ...han 5V a voltage divider must be used so that 5V at the maximum are applied at the device input Exceeding the 5V input voltage might cause damages to the device The relation between the two resistors...

Страница 5: ...Connecting a relay A connected relay is ideal to switch higher currents Since the field coil of the relay requires a higher current than provided by the measurement system at one line a transistor is...

Страница 6: ...AC OS X FreeBSD Linux UM LIBAD4 installation programming manual Operating program NV4 5 measuring software NextView 4 available in the Standalone versions Lite slim version with basic functions Pro fu...

Страница 7: ...Library 4 0 Delphi menu Components Import ActiveX entry LIBADX Object Library 4 0 If you select the entry STR LIBADX EX listed directly under the installation program of the corresponding ActiveX cont...

Страница 8: ...n drop 50ppm C 50ppm C Frequency accuracy Frequency drift max 50ppm max 50ppm C The total sampling rate is the sum of the sampling rates of the individual used channels e g if 4 channels are scanned w...

Отзывы: