background image

 

 USB-AD-OEM 

USB DAQ Device 

 

Really Simple. 

Record and output signals with the USB-
AD: The USB data acquisition system is 
ideal for universal applications in 
measurement and control technology. 
Implement your own ideas – just plug in 
and head off! 

OEM. Compact. Powerful. 
Budget Price. 

The idea behind the USB-AD-OEM: measuring 
where there is very little space. Mounting holes 
like 2,5“ HD/SSD mean, you can mount the 
USB-AD-OEMin a PC or any other housing. 

16 AIn. 1 AOut. 12 Bit. 

±

5V. 

Voltage signals in the ± 5V range are 
connected to 16 analog inputs. The sampling 
takes place with 12 bit resolution and up to 
160Hz total sampling rate. Analog controls are 
possible with the analog 12-bit output in the ± 
5V output range. 

16 Digital In-/Outputs. 

Digital states can be recorded or controlled in 
16 digital inputs and outputs. The direction of 
the digital lines can be selected in groups of 8. 

Plug & Play. 

The connection to the PC happens via USB. 
That way the USB-AD-OEM uses all USB-
typical features (eg. Plug & Play, Hot-Plug). Up 
to 127 devices can be connected and installed 
during operation. 

Powered by USB.  

The device is powered by the USB interface. 
This reduces the wiring effort to a minimum. 

Open for Windows. 

The measurement system receives extensive 
support from Windows® 8/10. All software for 
installing and programming the USB-AD-OEM 
is included free of charge. 

NextView

®

. Try For Free. 

The device is supported by NextView®, the 
software for measurement data acquisition 
and analysis. A fully functional 14-day trial 
version is included in the scope of delivery. 
This allows the functionality of the USB-AD-
OEM to be tested directly.

Functional Diagram 

 

Содержание USB-AD-OEM

Страница 1: ...l In Outputs Digital states can be recorded or controlled in 16 digital inputs and outputs The direction of the digital lines can be selected in groups of 8 Plug Play The connection to the PC happens...

Страница 2: ...through the USB connection 3a Step Measuring with NextView To be able to use your measurement system with NextView you just need to download and install the latest version of NextView on www nextview...

Страница 3: ...analog inputs with a measurement range of 5V and an analog output in the range of 5V Signals are connected via a 40 way pin connector The maximum potentials versus ground must not exceed 7V In the ev...

Страница 4: ...Vext 19 DGND 20 DGND 21 31 32 Vusb 33 34 D 35 36 D 37 38 DGND 39 40 The lines B1 B8 are set as output and A1 A8 as input in the default state The digital in and outputs are protected with 33W resistor...

Страница 5: ...and operation The board is equipped with four holes in the corners It can be fastened in a housing via bolts The hole spacing corresponds to the position of common HDD SSD 2 5 mounting holes M3 Conne...

Страница 6: ...make sure to use a push button with debounce protection because otherwise several pulses might be recorded The 3 9kW pull down resistor is optional in order to create a defined low signal even with lo...

Страница 7: ...ve the total current listed in the technical data see chapter 3 4 2 2 Connecting a Relay A connected relay is ideal to switch higher currents Since the field coil of the relay requires a higher curren...

Страница 8: ...to 10 values second per channel can be sampled depending on software and PC Surge protection max 12V when turned on max 7V when turned off max 20mA in total of all input channels Input resistance Inp...

Отзывы: