The analog channels can be reached externally at the D-Sub 37 female connector (P5, see Figure 1) on the
right side of the PC104-AD16. Two 20-way pin connectors P3, P4 allow the internal connection of current
shunts (ZU-CS250R optionally available).
The pin assignment in single-ended mode (PL10 and PL11 closed) is shown in the following figure and ta-
ble.
Assignment
D-Sub 37 female
20-way pin connector
single-ended / differential
(P5)
(P3/P4)
Analog inputs 1..8
Analog inputs 1A..8A
P5/1, P5/2, ... , P5/8
P3/1, P3/3, ... , P3/15
Analog inputs 9..16
Analog inputs 1B..8B
P5/9, P5/10, ... , P5/16 P3/17, P3/19, P4/1, P4/3, ..., P4/11
5V auxiliary voltage
P5/17
P4/13
Analog output 1 + 2
P5/18, P5/19
P4/15, P4/17
analog ground (AGND)
P5/20..35
P3/2, P3/4, ... , P3/20, P4/2, P4/4, ..., P4/12
output ground (OGND)
P5/36, P5/37
P4/14, P4/16
In differential mode (PL10 and PL11 connected), input 1 measures the voltage applied to pin 1 (A) and pin 9
(B) of the D-Sub 37 connector, for example. In reality, this operating mode is used for higher interference re-
sistance.
The pin assignment at the D-Sub 37 female P5 and the pin connectors P3, P4 is shown in the upper table and
following figure.