OR8/R8
Page 4
1.4.2
R8
Pin assignment and direction of the digital lines at the 25-pin D-Sub
male connector of the R8 are hard-wired. The control lines (TTL) for
the individual relay output channels OUT 1..OUT8 of an R8 have to
be applied to channels 1-8.
D-Sub25
Assignment
R8
USB-PIO (Port/Bit)
1
14
2
15
3
16
4
17
channel 1
channel 2
channel 3
channel 4
channel 5
channel 6
channel 7
channel 8
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
OUT8
A/0
A/1
A/2
A/3
A/4
A/5
A/6
A/7
If using a digital I/O system from bmcm (e.g. USB-PIO) connected 1:1 to the R8, port A of the USB-
PIO must be set to input.
2
Important notes for using the OR8/R8
•
The OR8 and the R8 are only suitable for extra-low voltages
–
please observe the relevant regulations!
•
An electrically isolated power unit (with CE) must be used for power supply.
•
All accessible pins are electrostatic sensitive devices. Provide for an earthed conductive work place when
installing.
•
Only use non-solvent detergents for cleaning. The product is designed to be maintenance-free.
•
The board must not be used for safety-relevant tasks. With the use of the product, the customer becomes
manufacturer by law and is therefore fully responsible for the proper installation and use of the product. In the
case of improper use and/or unauthorized interference, our warranty ceases and any warranty claim is
excluded.
Do not dispose of the product in the domestic waste or at any waste collection places. It has to be either duly
disposed according to the WEEE directive or can be returned to bmcm at your own expense.
3
Technical data (typical at 20°C, after 5min., +5V supply)
•
Electrical data
Power supply (OR8):
9..40V DC (ex works, solder jumper open) or +5V DC (solder jumper closed), ±5%, max. 4W
Power supply (R8):
+5V DC, ±5%, max. 0.7A DC, max. 3.5W
Input voltage:
5..30V
Input current (OR8):
max. 17mA; response time of the optocouplers <1ms
Relay data (OR8, R8):
max. current: 6A DC; response time: 10ms; live period: 100000 cycles
•
General data
Temperature range:
operating temp. 0..70 C, storage temp. -25..70 C
Relative humidity:
0-90% (not condensing)
CE standards:
EN61000-6-1, EN61000-6-3, EN61010-1; for decl. of conformity (PDF) visit
ElektroG // ear registration:
RoHS and WEEE compliant // WEEE Reg.-No. DE75472248
Dimensions (L x W x H):
OR8: 167mm x 105mm x 33mm; R8:160mm x 100mm x 20mm
Available accessories (optional):
DIN rail set ZU-EW (OR8: included with delivery),
connecting cable ZUKA25, waterproof housing ZU-PBOX-PG, ZU-PBOX-LAN
Warranty:
2 years from date of purchase at bmcm, claims for damages resulting from improper use excluded
Manufacturer: BMC Messsysteme GmbH. Subject to change due to technical improvements. Errors and printing errors excepted. Rev. 3.1
02/11/2020