background image

 

 

 

 

 

 

 

Installation, Operation & Maintenance 
Manual

 

For the Following Product-  

 

*2021 MODEL- BMB Nova Pro + Biocera A-A- 

Содержание Nova Pro

Страница 1: ...Installation Operation Maintenance Manual For the Following Product 2021 MODEL BMB Nova Pro Biocera A A...

Страница 2: ...t up diagrams Page 19 20 Use of push fits Page 21 Installation components Page 22 23 Installation steps Page 24 26 RO Membrane installation Page 27 Tank Installation Page 28 29 Start up and commission...

Страница 3: ......

Страница 4: ...found in water including microorganisms nitrates heavy metals insecticides and much more see Figure 1 on page 3 for a comparison of di erent ltration technologies Fig 2 on page 3 lists a more detaile...

Страница 5: ...atically ush the reverse osmosis lters afterwards to maintain water quality and extend lter lifetime The system works in the background to track water temperature errors and lter lifetime in order to...

Страница 6: ...tration Technology s spectrum Fig 2 Estimated Reverse Osmosis Rejection Percentages Figures given above are estimates of normal BMB Technology reverse osmosis membrane lter performance under normal co...

Страница 7: ...emove materials from the incoming water some lters actually add materials into water to improve the taste increase the mineral content and other health bene ts Although a Reverse Osmosis system can co...

Страница 8: ...ism in order to reduce the risk of leaks Once the lter is being changed simply keep twisting it into place slowly until a click is heard To remove the lter turn and hold the lock to open position with...

Страница 9: ...oconut Shell Carbon which has a very high capacity to reduce taste and odor compared to charcoal filters With a higher absorbent level Contaminants Reduced or Removed Chlorine chloramine pesticides he...

Страница 10: ...he open end of the leaf adhered to a perforated tube that runs up and down the center The membrane is constructed in this manner because unlike the pre lters which are designed as dead end ltration Re...

Страница 11: ...ntrated solution which is connected to the drain while the other port is the puri ed water less concentrated solution which is plumbed to the post lters Figure 5 on page 9 shows a detailed schematic o...

Страница 12: ...Page 9 of 44 Semipermeable Membrane Puri ed Water Post Filtration multi stage BIOCERA A A FILTERS 6 7...

Страница 13: ...Page 10 of 44...

Страница 14: ...system This duration should be reduced depending on how much the water quality exceeds the limits Please also see section 7 2 on how to adjust the lter change duration in the user interface If the fee...

Страница 15: ...Page 12 of 44 1 2 5 6 3 7 8 14 13 4 9 10 11 12...

Страница 16: ...er Measurespumpingpressure 7 Pump Increasesfeedwaterpressureto supplythereverseosmosismembrane ltersatoptimumosmoticpressure 8 DigitalController Controlsallsystemcomponents measuresTDSandregulates lte...

Страница 17: ...Page 14 of 44 post filters Reverse osmosis membranes...

Страница 18: ...ntenance Since the system is wet tested after assembly it is shipped with plugs on all of the ports in order to prevent any potential leaking in the box from residue water that may be left after testi...

Страница 19: ...hole for faucet 12 mm or 1 2 diamond tip drill bit Main hole for faucet stem 7 mm or tip drill bit Tubing hole for drain saddle Adjustable Wrench Installing feed water diverter valve metal ball valve...

Страница 20: ...el is a system that can be used for both residential and commercial applications The system is a direct ow model tankless that does not ship with a tank Consequently all puri ed water is instantaneous...

Страница 21: ...feed water pressure or high capacity use the BMB Nova Pro model can be installed with a tank For these situations simply remove the quick connect plug on the Tank water connection port of the system a...

Страница 22: ...e union the teeth are forced deeper into the tubing preventing separation of the union The advantages of using quick connect ttings are They o er a signi cant time saving bene t over traditional conne...

Страница 23: ...tubing before it seals Lightly push the tubing into the tting until the grip is felt Step 4 Now push the tubing into the tting harder until the tube stop is felt The collet has stainless steel teeth w...

Страница 24: ...Page 21 of 44 Nova pro installation components Saddle connection PTFE Tape Feed connection 3 8 3 4 supplied 3 8 1 4 tubing Elbow connections Faucet Tap Faucet tap connection kit...

Страница 25: ...n for nova pro 2 Check for Electrical socket install new socket or use extension cable 3 Install supplied faucet tap or install upgraded 3 way tap 4 Install Feed connection on cold water tap connectio...

Страница 26: ...ain to pass through Clean the debris from the plumbing and hold before continuing Remove the backing from the foam gasket and stick that half of the drain saddle on the drain pipe so that the holes li...

Страница 27: ...nstall remove all plugs in connection ports to release any system pressure build up Replace TANK plug Remove housings as illustrated below and use supplied key to open membrane housing This can be ver...

Страница 28: ...Page 25 of 44...

Страница 29: ...nections Connect Feed water Drain Water Clean Water Use Elbow connections if required on Nova pro Ports When replacing RO Membranes after usage lifespan please refer to Pre Post filter change Page 35...

Страница 30: ...Page 27 of 44 7a Install TANK if required Use PTFE tape to connect tank valve to tank and connect with tubing to TANK port on Nova Pro...

Страница 31: ...next enter the pump cycle which also can be observed from the digital panel In this process the system will start producing water which can be seen running from the faucet The system should run with t...

Страница 32: ...open the top cover of the system and look for leaks inside Again while the system is in the Tank Full mode read the Inlet Pressure and make sure that it is above 2 5 bars If it is below 2 5 bar a tank...

Страница 33: ...Press once and release to ush the membranes and bring fresh water into the system When 30 days remain until end of lter lifetime the controller will make a sound alarm every 12 hours to remind the us...

Страница 34: ...er each time system is re pressurized Lights when system is in standby mode Approximate temperature of produced water POWER NO WATER PUMP FLUSH TANK FULL cartridge change PPM 1 2 3 4 5 Filter lifetime...

Страница 35: ...ow down This is true because the lters are made from organic compounds such as paper coconut shell minerals etc and they will degrade in water over time Additionally changing of the lters is a Prevent...

Страница 36: ...extended non use 1 Close the feed water valve that supplies the system 2 Open the faucet until no more water comes from the faucet 3 System will give a No Water alarm this is OK 4 Turn o the system f...

Страница 37: ...no tubing bends more than 45 degrees Loss of air pressure in tank Empty tank and pressurize to 6 8 PSI Controller cycles between No Water Pump Flush Low feed water pressure Make sure the feed water pr...

Страница 38: ...electrical connection lift out of position change filters as shown Pre filters The pre lters have a locking mechanism on the top to make it easy for lter change In order to remove old lters from the...

Страница 39: ...have quick connect tubing and tting connections Simply remove the inlet and exit quick connect tting elbows for the post lters and replace with the new filters To change membranes refer back to page 2...

Страница 40: ...Page 37 of 44 SERVICE FILTER CHANGE LOG Model NOVA PRO Date of Purchase Date of Install Installed By Date Pre Filter Post Filter Change Membrane Change Other...

Страница 41: ...send a copy to your BMB Technology dealer or BMB Technology Headquarters by simply taking a picture of it with your smart phone and mailing it to info bmbtechnology com First Name LastName FullAddres...

Страница 42: ...ntal factors water pressure spikes or other similarfactors Normal wear and tear Accidental damage or faults caused by negligent use or care misuse neglect careless operation and failure to use the sys...

Страница 43: ...Page 40 of 44...

Страница 44: ...Page 41 of 44...

Отзывы: