34
EN
TROUBLESHOOTING
If the problem is:
And this condition exists:
Then do this:
Pilot won’t light .
Cylinder valve is closed
Open valve
Blockage in orifice or pilot
tube
Clean or replace orifice or
pilot tube
Air in the gas line
Open gas line and bleed
it (pressing control knob
in) for not more than 1-2
minutes or until you smell
gas
Low gas pressure
Gas cylinder low or empty
Pilot won’t stay lit.
Dirt build up around pilot
Clean dirt from around
pilot
Connection between gas
valve and pilot assembly
is loose
Tighten connection and
perform leak test
Bad thermocouple
Replace thermocouple
Burner won’t light..
Dirt build up around pilot
Replace gas cylinder
Connection between gas
valve and pilot assembly
is loose
Clear blockage
Bad thermocouple
Turn control knob to "ON"
position
Burner flame is low .
Note: Do not operate the
appliance below 5 °C (40 °F).
Gas pressure is low
Replace gas cylinder
Outdoor temperature is
greater than 5℃(40°F) and
tank is less than 25% full
Replace gas cylinder
Supply hose is bent or
kinked
Straighten hose and
perform leak test on hose
Control knob is fully " ON"
Turn control knob to
"OFF", let it cool to room
temperature and check
burner and orifices for
blockage
Содержание 10034280
Страница 2: ......
Страница 9: ...9 DE Decke Wand ...
Страница 20: ......
Страница 27: ...27 EN ...
Страница 37: ......
Страница 38: ......
Страница 39: ......
Страница 40: ......