background image

 

B. 

General Information

 

This manual provides information relating to the installation, utilization and maintenance of our filtration system. 
We recommend that you read this manual in its entirety and keep it for future reference, 
The  pump  included  with  the  filtration  system  is  a  horizontal,  self-priming  centrifugal  pump.  For  the  pump  to 
function  correctly,  the  water  temperature  must  not  exceed  35℃/95℉.  The  materials  used  in  the  pump  have 
undergone stringent hydraulic testing and electrical inspections. 
The filter tank included in the filtration system consists of high-grade polypropylene (PP). It is manufactured as a 
single  unit  (absolutely  corrosion  resistant  and  resistant  to  commercially  available  swimming  pool  chemicals). 
(Prerequisite:  Compliance  with  the  standard  recommended  specifications  for  the  pH-  and  chlorine  value).  It  is 
equipped with a tank drainage system, pressure gauge. The filter tank comes ready to attach and is supplied with a 
user-friendly 7 Position Multi-Port Valve attached to the tank cover, an approved filter pump with hair and

 

lint 

basket, and a plastic base for ready on- site mounting. 

Read this manual carefully before installation.

 The filtration system and pump must be installed in accordance 

with all federal and local codes and standards in effect for the area of installation. 
We  decline  all  responsibility  for  the  consequences  of  failure  to  comply  with  the  installation  instructions.  We 
recommend  that  you  comply  with  the  power  source  instructions  to  avoid  overloading  the  pump  motor  and/or 
electric shock. 
This filtration system is not intended for use by persons with reduced physical, sensory or mental capabilities, or 
lack of experience and knowledge. 
Safety notes and information boxes should always be observed. 

C. 

Safety Notes

 

Your filter pump was constructed and tested and left the manufacturing plant in technically operational condition. 
In  order  to  maintain  this  condition  and  ensure  safe  operation,  the  user  should  observe  the  notes  and  product 
information contained in this technical manual. If there is any indication that safe operation is no longer possible, 
the device is to be disconnected from the power supply and secured against accidental use. 
This is the case when: 

 

The device has visible damage.   

 

The device no longer appears functional. 

 

After long periods of storage in poor conditions. 

If the power cord or other parts of this equipment are damaged, they have to be replaced by the manufacturer or its 
service agent or a similarly qualified person in order to avoid danger. 

D. 

Damage during delivery

 

Your  filter  system  has  been  carefully  and  professionally  packed  for  delivery.  Please  check  to  ensure  that  the 
package  is  undamaged  and  that  all  parts  are  in  the  box  (see  the  parts  lists  at  the  end  of  this  manual).  If  you 
purchased this product on order and the product was shipped to you, ensure that delivery is complete. Damage to 
product as a result of shipping is not the responsibility of the supplier and must be immediately reported to the 
shipper. The shipper assumes the liability for damages during delivery, the supplier is not responsible for it. 

E. 

Implied Warranty

 

The manufacturer warranties safe operation and reliability only under the following conditions: 

 

The filter system is installed and operated according to the assembly and operating instructions. 

Содержание FlowXtreme NE4487

Страница 1: ...VER 1219 A Above Ground Po ool Filter r Pump p Manua al NE4487 NE4488 NE4489 ...

Страница 2: ...d electrical outlet Consult and follow all local and national codes related to swimming pools and their equipment Incorrectly installed equipment may fail causing severe injuries or damage to the pump filter system Never submerge the filter and or pump in water Never place the pump or filter in your pool Trapped air in the pump filter system may cause the TANK COVER to be blown off which can resul...

Страница 3: ...stem is not intended for use by persons with reduced physical sensory or mental capabilities or lack of experience and knowledge Safety notes and information boxes should always be observed C Safety Notes Your filter pump was constructed and tested and left the manufacturing plant in technically operational condition In order to maintain this condition and ensure safe operation the user should obs...

Страница 4: ...e 2100 GPH 2300 GPH 5400 GPH MAX Operating Pressure 22 psi 22 psi 22 psi Related Voltage 110V AC 60Hz 110V AC 60Hz 110V AC 60Hz Power 1 2HP 3 4 HP 1 HP Amount of Sand Max 35lbs Max 75lbs Max 100lbs Pool size Max 4 000 US gallons Max 8 000 US gallons Max 20 000 US gallons H Unpacking your filter system Carefully remove the product and all component parts from the box Cross reference all parts in th...

Страница 5: ... difficult to move around Check to ensure that the bottom strainer is correctly positioned Check to ensure that the tank separator plate is seated properly Check to ensure that the upper distributor is located under the tank cover Fill the sand chamber half full with water Pour 20 Pool Filter Grade silica sand into the SAND FILTER CHAMBER being careful not to allow any sand to enter the FILTERED W...

Страница 6: ... the instructions on proper power supply sources Once the filter system has been properly assembled the tank filled with sand and the hoses connected as described you may begin filtration However we recommend that you first clean and prepare the new sand Cleaning the sand prior to filtering your pool will remove most of the dust and tiny sand particles that may exist in the sand If you move straig...

Страница 7: ... most of the time In this position water is directed through the top of the filter where it compresses and flattens down the sand Contaminations are trapped by the sand as water makes it way to the bottom strainer out of the filter and back to the pool Rinse Position 2 Picture 20 Function Use after backwashing to clean the filter bed This should always be done immediately after backwashing new san...

Страница 8: ...onnect the filtration system from the pool drain the tank and hoses Place the handle on the central valve in position 7 Winterize to relieve the tension on the spring and internal valve components This prevents the Diverter Gasket from becoming stuck to the gasket seat over the winter and damaged in the spring start up procedure Store the filter system in a location protected from frost and severe...

Страница 9: ... has reading more than 10 PSI over the normal filtering pressure Dirty filter bed Backwash the filter position 4 Pressure is too low Hair and lint strainer basket is dirty Pump gets too little water Clean the hair and lint strainer check the suction line and the water level Air in the pump Poor seal on the intake side of pump Tighten hose clamps and connecting fittings Leaking filter Seal Defectiv...

Страница 10: ...S Install lation and d Operati ion Illustr 9 ration Fig gures ...

Страница 11: ... I00162 NEP4235 NE4487 4488 4489 15 1 1 4 O Ring For Long INTEX Connector 1 I00163 NEP4236 NE4487 4488 4489 16 View Port Cover 2 T00164 NEP4284 NE4487 4488 4489 17 Gasket For View Port Cover 2 T00165 NEP4285 NE4487 4488 4489 18 Seal Washer For Valve Cover Stems 9 V00166 NEP4296 NE4487 4488 4489 19 Valve Cover Screws 9 V00167 NEP4297 NE4487 4488 4489 20 Tank Seal 1 T00168 NEP4286 NE4487 4488 4489 2...

Страница 12: ...44 NE4489 33 Hose Clamp 1 P00174 NEP4260 NE4487 33 Hose Clamp 2 P00174 NEP4260 NE4488 4489 34 Pump Bolt Wing Nut PUMP MOUNTING HARDWARE 2 P00175 NEP4261 NE4487 4488 4489 35 Pump Bolt Flat Water PUMP MOUNTING HARDWARE 2 P00176 NEP4262 NE4487 4488 4489 36 Pump Bolt Lock Washer PUMP MOUNTING HARDWARE 2 P00177 NEP4263 NE4487 4488 4489 37 Pump Bolt Nut PUMP MOUNTING HARDWARE 2 P00178 NEP4264 NE4487 448...

Страница 13: ...12 ...

Страница 14: ...P4248 NEP4268 NEP4269 NE4523 9 Pump Drain Cap 1 P00135 NEP4249 NEP4268 NEP4269 NE4523 10 Drain Valve O ring 1 P00136 NEP4250 NEP4268 NEP4269 NE4523 11 Motor Pump Seal 250 1 P00137 NEP4251 NEP4268 NEP4269 NE4523 11 Motor Pump Seal 450 1 P00138 NEP4252 NEP4268 NEP4269 NE4523 11 Motor Pump Seal 550 1 P00138 NEP4252 NEP4268 NEP4269 NE4523 12 Impeller Assembly 250 1 P001392 NEP4253 NEP4268 12 Impeller ...

Страница 15: ...ps Pa NEP427 y Mnfg SPS3 1 SPS3 1 3029 3030 3031 3032 3033 3034 3035 3036 3037 3038 3039 3040 3041 3042 3043 3044 arts Break 71 NE452 No B W 1100 NEP 1600 NEP S3 NEP S3 NEP S3 NEP S3 NEP S3 NEP S3 NEP S3 NEP S3 NEP S3 NEP S3 NEP S3 NEP S3 NEP S3 NEP S3 NEP S3 NEP S3 NEP kdown 24 W No P4271 P4254 P4128 N P4129 N P4130 N P4131 N P4132 N P4133 N P4134 N P4135 N P4136 N P4137 N P20202 N P20203 N P2020...

Страница 16: ...e with ump operating ctions open s circuit breaker or shaft for fre t is working pr drop frequen ssional to chec to direct sunlig ure uniform a ipped with an 15 reme Prim h the wiring di g label switches or rel rs and fuses R ee movement roperly Bypa ntly caused by ck that the wir ght or low wa amount of wat automatic th me Pump iagram on mot lays tripped c Reset tripped and lack of ob ass it if n...

Страница 17: ...ll help to create a tighter seal 2 Loose connections on suction side Solution Tighten pipe union connections or hose clamps on flexible hose NOTE Any self priming pump will not prime if there are suction air leaks Leaks will result in bubbles emanating from return fittings on In Ground pool wall 3 Leaking O ring on valves Solution Tighten repair or replace valves 4 Strainer basket or skimmer baske...

Страница 18: ...t the grease resulting in rusting of the motor shaft and causing the bearing to whine Solution All seal leaks must be replaced at once Have a qualified pump repair specialist replace the motor shaft seals and inspect the motor shaft for possible damage If the motor shaft is damaged replace the motor Water Leaks Around Intake and Discharge fittings Check For 1 Lose union fittings or hose fittings S...

Страница 19: ...on or replacement of the product or components are not covered under this warranty The manufacturer reserves the right to make substitutions to warranty claims if parts are unavailable or obsolete The manufacturer shall not be liable for loss of use of the product or other consequential or incidental costs expenses or damages incurred by the consumer of any other use The user assumes all risk of i...

Страница 20: ...uit ou de ses composantes ne sont pas couverts par cette garantie Le fabricant se réserve le droit de faire des substitutions de recours en garantie si la pièce n est pas disponible ou obsolète Le fabricant décline toute responsabilité liée à la perte d utilisation ainsi que tous les autres coûts directs ou indirects frais ou dommages encourus par le consommateur qui aurait été causés par une autr...

Отзывы: