background image

06

08

07

Accessories & Tools

Attentions

Installation Steps

YD8

24V LED Power supply

SA2-01 connector

M3 self-tapping screw

Electric drill

Clean the mounting surface.

Peel off the release paper backside 

the rigid bar.

Distribute the rigid bars in the light 

box according to proper spacing. Be 

careful not to damage lens, LEDs 

and electronic components of the 

rigid bar.

Screw to fix the bar.

If the bar need to be jointed, please 

arrange it as the picture shows.

Note: Do not excess the standard 

series connection.

Connect the SA2-01 connector.

Connect the main line of rigid bar to 

the 24V power supply.

Note: Treat the wire end with 

insulation,waterproof, and anti-

corrosion arrangement as it cannot 

pull out by hands.

Load voltage, current, power and power supply should be matched with the product.

Follow the instructions of wiring diagram to avoid short circuit.

The main line connected to the rigid bar should be thicker to prevent inconsistent 

brightness  due to excessive line loss.

Make sure the power cord firmly screwed into the terminal as it can not be pulled out 

by hands, and the terminal should have insulation,waterproof and anti-corrosive 

treatment.

Use  standard  output  voltage:  DC24V.  The  power  supply  line  with  safety 

certification(with short circuit protection, over-voltage protection and over-current 

protection, the output voltage adjustment rate of switching power supply is±%5 ) 

should retain a load margin greater than 15% .

Do not remove or modify LED, and do not touch or scratch the LED with sharp objects.

Do not do live-line working during installation.

Do not use any chemical solvents.

Treat the ends and the circuit connection points that are not connected to the main line 

with insulation,waterproof, and anti-corrosion in the installation.

Use thicker core wire to avoid adverse consequences caused by overheating if the 

power cable need to lengthen.

Make sure the input voltage meets the requirements and lines are connected correctly 

before lighting on.

This product is used inside of the light box or signage, and do not use it directly in 

outdoor and semi-outdoor situation.

Installation and maintenance must be done by professionals.

The length of the power cable between the power supply and the Product should not 

exceed 2 meters. Otherwise, large circuit loss will lead to inconsistent brightness.

09

Common Faults and Troubleshoot

Quick Guide

Problems

All LEDs can 

not light on.

LEDs can not

light on partly.

Brightness of 

LED 

is inconsistent

tor insufficient.

LED flicker.

Automatic power protection 

from the open or short circuit in 

output of the power supply.

Fix the short circuit problem.

Check the power supply system to 

fix it.

Replace with more powerful power 

Make sure working voltage of the 

product within ±5% of standard 

voltage, or keep balance by circuit 

power consumption.
Reduce the quantities of the 

product in series connection to 

meet requirement.

Supply electricity.

Some switching mode power 

supplies are not powered.

Power supply line error.

Power overloaded.

Connection point fault.

Remove bad connection point.

Replace a new power supply.

Power supply circuit

excessive consumption.

Excessive quantities in series 

connection of the product.

Switching power supply failure.

Reasons

No electric supply.

Solutions

10

Warning

11

Statements and Recycling

Repair should be operated by a qualified technician, if the external circuit or main line of 

this product is damaged.

The parameters given in this manual are typical values and for reference only.

All illustrations and drawings in this manual are for reference.

This product is subject to change without notice.

LED lighting products belongs to electronic products, please do recycling treatment 

according to the relevant WEEE directives.

Statements:

Recycling:

Отзывы: