Hardware User Manual - Argos3D – P100
Last change: 22 August 2013
Version
1.5
7
Appendix
7.1
Operating Conditions
Symbol
Parameter
Min
Typical
Max
Unit
V
IN
Input supply voltage
4.9
5.0
5.2
V
I
IN
Input current
1)
TBD
900
1)
TBD
mA
T
OP
Operating Temperature
0
+65
2)
°C
T
STG
Storage Temperature
-40
+125
°C
FITP
3)
Frame-rate Integration Time Product
550
Table 7-1: Operating Conditions
1) Note
Valid for a frame-rate of 40fps and an integration time of 1500µs. The input current depends on
the applied frame-rate and integration time. Please refer to 7.1.1.
2) Note
The maximum operating temperature depends on the frame-rate and integration time. Refer to
Figure 2-1 for recommended integration time to frame-rate combinations.
3) Note
Refer to 7.4.2 for valid frame-rate to integration time combinations.
7.1.1
Input current
The input current depends on the selected frame-rate (fps) and the integration time (t
INT
). The following figure
shows typical values. The values for the x axis shows the Frame-rate Integration Time Product (FITP) which
is calculated as follow:
𝐹𝐹𝐹𝐹𝐹𝐹𝐹𝐹
=
𝑡𝑡
𝐼𝐼𝐼𝐼𝐼𝐼
[
𝑚𝑚𝑚𝑚
]
∙ 𝑓𝑓𝑓𝑓𝑚𝑚
�
1
𝑚𝑚
� ∙
4
© Bluetechnix 2013
Page | 13
Содержание Argos3D - P100