background image

Contents

Safety  Notice    ...............................................................        02

Unit  Illustration

Important  Testing  Guidelines 

Quick  Start      .................................................................      10

Blood  Pressure  Information

Blood  Pressure  Q

A

Maintenance

Specifications

      .........................................................        06 

    .....................................        09

Unit  Operation      ...........................................................        12

      ........................................      26

      ...................................................      30

      ...............................................................      32

      .............................................................        36

Limited Warranty   .........................................................     41

   Battery Installation  ..................................................   12

   System Settings  ........................................................    13  

   Applying The Wrist Monitor   ....................................   15

   Testing   .....................................................................   17

   Power Off   .................................................................   21

   Memory Check   ........................................................    22

   Memory Deletion   .....................................................  23

   Low Battery Indicator   .............................................    24

   Troubleshooting   ......................................................    25

Safety Notice

Safety Notice

Safety Notice

Owner's Manual

Automatic Wrist 

Digital Blood Pressure Monitor

Model

  80-5103

1

3

2

4

Wrist Type

Thank you for purchasing the 80-5103 Blood Pressure Monitor. 

The unit has been constructed using reliable circuitry and 

durable materials. Used properly, this unit will provide years

of satisfactory use.

7.To avoid any possibility of accidental strangulation, keep this 

    unit away from children and do not drape tubing around your 

    neck.

8.Ensure that children do not use the instrument unsupervised;

    some parts are small enough to be swallowed.

9.Some may get a skin irritation from the cuff taking frequent  

   readings over the course of the day, but this irritation typically 

   goes away on its own after the monitor is removed.

The device is intended for used by adults with 12 years and older 

to measure the systolic and diastolic  blood  pressure  and pulse  

rate. All values can be read out in one LCD DISPLAY. 

Measurement position is on adult upper arm only.

Blood pressure measurement determined with this device are 

equivalent to those obtained by a trained observer using the 

cuff/ stethoscope auscultation method, within the limits 

prescribed by the American National Standard (ANSI/AAMI 

Sp10) for electronic sphygmomanometers.

Precautions to Ensure Safe, Reliable Operation

1. Do not drop the unit. Protect it from sudden jars or shocks.

2. Do not insert foreign objects into any openings.

3. Do not attempt to disassemble the unit.

4. Do not crush the pressure cuff.

5. If the unit has been stored at temperatures below 0 

o

C, leave it 

    in a warm place for about 15 minutes before using it. 

    Otherwise, the cuff may not inflate properly.

6. Do not store the unit in direct sunlight, high humidity or dust.

Document No. DBP-2504-003

Important Instructions Before Use
1. Do not confuse self-monitoring with self-diagnosis. 
    Blood pressure measurements should only be interpreted by a 
    health professional who is familiar with your medical history.
2. Contact your physician if test results regularly indicate 
    abnormal readings.
3. If you are taking medication, consult with your physician to 
    determine the most appropriate time to measure your blood 
    pressure. NEVER change a prescribed medication without first 
    consulting with your physician.
4. Individuals with serious circulation problems may experience 
    discomfort. Consult your physician prior to use.
5. For persons with irregular or unstable circulation resulting 
    from diabetes, liver disease, arteriosclerosis or other medical 
    conditions, there may be variations in blood pressure values 
    measured at the wrist versus at the upper arm. Monitoring the 
    trends in your blood pressure taken at either the arm or the wrist 
    is nevertheless useful and important.
6. People suffering from vascular constriction, liver disorders or 
    diabetes, people with cardiac pacemakers or a weak pulse, and 
    women who are pregnant should consult their physician before 
    measuring their blood pressure themselves. Different values 
    may be obtained due to their condition.

7. People suffering from arrhythmias such as atrial or ventricular 
    premature beats or atrial fibrillation only use this blood pressure 
    monitor in consultation with your doctor. In certain cases 
    oscillometric measurement method can produce incorrect 
    readings.

8.Too frequent measurements can cause injury to the patient due to 
    blood flow interference.
9.The cuff should not be applied over a wound as this can cause  
    further injury.
10.

DO NOT 

attach the cuff to a limb being used for IV infusions or

      any other intravascular access, therapy or an arterio-venous  (A-
      V) shunt. The cuff inflation can temporarily block blood flow, 
      potentially causing harm to the patient.
11.The cuff should not be placed on the arm on the side of a 
      mastectomy. In the case of a double mastectomy use the side of 
      the least dominant arm.
12.Pressurization of the cuff can temporarily cause loss of function 
      of simultaneously used monitoring equipment on the same limb.
13.A compressed or kinked connection hose may cause continuous 
     cuff pressure resulting in blood flow interference and potentially 
     harmful injury to the patient.
14.Check that operation of the unit does not result in prolonged 
      impairment of the circulation of the patient.

Version: Z

Date of Issue: 2012.11

Manufactured for:
Trademark Global LLC
Lorain, OH 44053
Made in China

Содержание 80-5103

Страница 1: ...ments should only be interpreted by a health professional who is familiar with your medical history 2 Contact your physician if test results regularly indicate abnormal readings 3 If you are taking me...

Страница 2: ...st See Figure C 3 Plastic Storage Case World Health Organization WHO Blood Pressure Classification Indicator Monitor Unit Systolic Blood Pressure mmHg kPa No M D Time Date Pulse Rate Low Battery Indic...

Страница 3: ...2 new AAA alkaline batteries according to polarity Close battery cover Note 1 2 Batteries should be removed from device when not in operation for an extended period of time Replace batteries when Low...

Страница 4: ...ously on screen signaling heart beat detection Note Remain relaxed during testing Avoid speaking or moving body parts 4 Result Display Three short beeps sound when testing is complete The screen will...

Страница 5: ...Make sure hose is properly fastened to cuff and monitor unit Improper operation Read user manual carefully and re test properly Read user manual carefully and re test properly Pressurization is over 3...

Страница 6: ...intenance 3 When cleaning the unit use a soft fabric and lightly wipe with mild detergent Use a damp cloth to remove dirt and excess detergent 4 Do not soak cuff in water Cuff Cleaning Apply a small a...

Страница 7: ...safety EN 60601 1 2 Medical electrical equipment part 1 2 General requirements for safety Collateral standard Electromagnetic compatibility Requirements and tests EN 1060 1 Non invasive sphygmomanomet...

Отзывы: